Model

Speed

CFM deliverd against External Static Pressure

 

 

 

 

 

 

 

0.1"

0.2"

0.3"

0.4"

0.5"

 

High

1155

1090

1025

950

895

 

 

 

 

 

 

 

ARUF172916

Med.

940

890

860

815

755

 

 

 

 

 

 

 

 

Low

695

665

650

610

550

 

 

 

 

 

 

 

 

High

1155

1090

1025

950

895

 

 

 

 

 

 

 

ARUF182416

Med.

940

890

860

815

755

 

 

 

 

 

 

 

 

Low

695

665

650

610

550

 

 

 

 

 

 

 

 

High

1135

1085

1025

965

915

 

 

 

 

 

 

 

ARUF193116

Med.

860

825

780

750

680

 

 

 

 

 

 

 

 

Low

600

570

545

500

465

 

 

 

 

 

 

 

 

High

1385

1315

1240

1155

1065

 

 

 

 

 

 

 

ARUF303016

Med.

1340

1290

1230

1140

1050

 

 

 

 

 

 

 

 

Low

1075

1030

980

910

840

 

 

 

 

 

 

 

 

High

1310

1240

1155

1090

1020

 

 

 

 

 

 

 

ARUF363616

Med.

1270

1210

1140

1075

980

 

 

 

 

 

 

 

 

Low

1045

1005

955

885

805

 

 

 

 

 

 

 

 

High

1700

1660

1625

1545

1505

 

 

 

 

 

 

 

ARUF364216

Med.

1500

1440

1400

1350

1345

 

 

 

 

 

 

 

 

Low

1330

1300

1250

1230

1220

 

 

 

 

 

 

 

 

High

2065

2000

1925

1860

1780

 

 

 

 

 

 

 

ARUF374316

Med.

1685

1635

1550

1470

1410

 

Low

1490

1425

1345

1280

1205

 

 

 

 

 

 

 

 

High

2150

2120

2070

2000

1940

 

 

 

 

 

 

 

ARUF486016

Med.

1940

1930

1905

1860

1790

 

Low

1610

1600

1590

1575

1550

 

 

 

 

 

 

 

 

High

2150

2105

2040

1970

1880

 

 

 

 

 

 

 

ARUF496116

Med.

1960

1935

1895

1825

1750

 

Low

1670

1625

1585

1525

1455

NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)

Model

Speed

CFM deliverd against External Static Pressure

 

 

 

 

 

 

 

0.1"

0.2"

0.3"

0.4"

0.5"

 

High

1155

1090

1025

950

895

 

 

 

 

 

 

 

ARPF18241*

Med.

940

890

860

815

755

 

 

 

 

 

 

 

 

Low

695

665

650

610

550

 

 

 

 

 

 

 

 

High

1135

1085

1025

965

915

 

 

 

 

 

 

 

ARPF19311*

Med.

860

825

780

750

680

 

 

 

 

 

 

 

 

Low

600

570

545

500

465

 

 

 

 

 

 

 

 

High

1385

1315

1240

1155

1065

 

 

 

 

 

 

 

ARPF30301*

Med.

1340

1290

1230

1140

1050

 

 

 

 

 

 

 

 

Low

1075

1030

980

910

840

 

 

 

 

 

 

 

 

High

1310

1240

1155

1090

1020

 

 

 

 

 

 

 

ARPF36361*

Med.

1270

1210

1140

1075

980

 

 

 

 

 

 

 

 

Low

1045

1005

955

885

805

 

 

 

 

 

 

 

 

High

1700

1660

1625

1545

1505

 

 

 

 

 

 

 

ARPF36421*

Med.

1500

1440

1400

1350

1345

 

 

 

 

 

 

 

 

Low

1330

1300

1250

1230

1220

 

 

 

 

 

 

 

 

High

2065

2000

1925

1860

1780

 

 

 

 

 

 

 

ARPF37431*

Med.

1685

1635

1550

1470

1410

 

 

 

 

 

 

 

 

Low

1490

1425

1345

1280

1205

 

 

 

 

 

 

 

 

High

2150

2120

2070

2000

1940

 

 

 

 

 

 

 

ARPF48601*

Med.

1940

1930

1905

1860

1790

 

 

 

 

 

 

 

 

Low

1610

1600

1590

1575

1550

 

 

 

 

 

 

 

 

High

2150

2105

2040

1970

1880

 

 

 

 

 

 

 

ARPF49611*

Med.

1960

1935

1895

1825

1750

 

 

 

 

 

 

 

 

Low

1670

1625

1585

1525

1455

 

 

 

 

 

 

 

NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)

Model

Speed

CFM deliverd against External Static Pressure

 

 

 

 

 

 

 

0.1"

0.2"

0.3"

0.4"

0.5"

 

High

1,155

1,090

1,025

950

895

 

 

 

 

 

 

 

ADPF18241/16

Med.

940

890

860

815

755

 

 

 

 

 

 

 

 

Low

695

665

650

610

550

 

 

 

 

 

 

 

 

High

1,700

1,660

1,625

1,545

1,505

 

 

 

 

 

 

 

ADPF30421/16

Med.

1,500

1,440

1,400

1,350

1,345

 

 

 

 

 

 

 

 

Low

1,370

1,300

1,250

1,230

1,220

 

 

 

 

 

 

 

 

High

2,150

2,120

2,070

2,000

1,940

 

 

 

 

 

 

 

ADPF48601/16

Med.

1,940

1,930

1,905

1,860

1,790

 

 

 

 

 

 

 

 

Low

1,610

1,600

1,590

1,575

1,550

NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)

Model

Speed

CFM deliverd against External Static Pressure

 

 

 

 

 

 

 

0.1"

0.2"

0.3"

0.4"

0.5"

 

High

1155

1090

1025

950

895

ATUF182416

Med.

875

830

790

750

715

 

Low

640

610

570

535

490

 

High

1135

1085

1025

965

915

 

 

 

 

 

 

 

ATUF193116

Med.

860

825

780

750

680

 

Low

600

570

545

500

465

 

High

1455

1385

1330

1205

1090

ATUF303016

Med.

1340

1290

1230

1140

1050

 

Low

1075

1030

980

910

840

 

High

1345

1290

1230

1150

1070

ATUF363616

Med.

1270

1210

1140

1075

980

 

Low

1045

1005

955

885

805

 

High

1700

1680

1645

1610

1535

 

 

 

 

 

 

 

ATUF364216

Med.

1500

1480

1440

1380

1325

 

Low

135

1320

1275

1230

1195

 

High

2065

2000

1925

1860

1780

ARUF374316

Med.

1685

1635

1550

1470

1410

 

Low

1490

1425

1345

1280

1205

 

High

2135

2080

1985

1900

1805

ATUF486016

Med.

1975

1935

1875

1775

1675

 

Low

1715

1670

1650

1590

1530

NOTE: Assumes dry coil with filter in place; SCFM correction for wet coil = 4% (208V/240V)

ASPF Motor

The ASPF air handler features an energy efficient blower motor. The motor is a constant torque motor with very low power consumption. The motor is energized by 24 VAC. Ad- just the CFM by changing the 24 VAC leads to the desired speed on the terminal block.

The ASPF motor blower speed is programmed to deliver ad- equate airflow at rated external static pressure and with 60 second off time delay. For details, refer to the specification sheet applicable to your model.

CFM Delivery

Table 13 shows the CFM speed tap settings for the ASPF.

Thermostats

NOTE: Second Stage heat can be accomplished by multi- stage heating thermostat or the addition of an outdoor

10

Page 10
Image 10
Goodman Mfg ARUF, ATUF, ASPF, ADPF installation manual Aspf Motor, Thermostats

ATUF, ADPF, ASPF, ARUF specifications

Goodman Manufacturing is synonymous with quality and reliability in the HVAC industry, offering a wide range of air handling units, including the ARUF, ASPF, ADPF, and ATUF series. These products showcase advanced technologies while providing cost-effective solutions for residential and commercial applications.

The ARUF series is designed specifically for reliable indoor air management. These air handlers are known for their high-efficiency performance and compact design, making them suitable for tight spaces. They feature an insulated cabinet that minimizes noise and energy loss, ensuring a quieter operation and increased comfort. The ARUF units also have a multi-speed blower motor, which provides improved airflow and better temperature control, enhancing overall system efficiency.

The ASPF series stands out with its variable-speed motor technology. This innovation allows for precise airflow adjustments, adapting seamlessly to changing thermal loads within the space. Such adaptability not only improves comfort levels but also leads to energy savings by optimizing performance during varying usage periods. Additionally, the ASPF air handlers are designed for easy installation, incorporating lightweight components and a versatile design that accommodates different configurations and applications.

Meanwhile, the ADPF series is highly regarded for its durability and performance in moisture-rich environments. Engineered with a robust housing, the ADPF units offer increased corrosion resistance, making them ideal for locations susceptible to humidity. The units come equipped with enhanced filtration capabilities, ensuring improved indoor air quality by capturing dust, pet dander, and other allergens effectively.

Lastly, the ATUF series combines advanced technology with user-friendly features. These units feature a high-efficiency air filter and a low-profile design, perfect for a variety of applications. The ATUF air handlers come equipped with integrated control systems that allow users to easily adjust settings and monitor performance, ensuring optimal operation over time.

In summary, Goodman Manufacturing's ARUF, ASPF, ADPF, and ATUF air handling units showcase cutting-edge technologies, robust construction, and energy-efficient designs. Each series offers unique features tailored to meet the diverse needs of customers, ensuring enhanced comfort and cost savings in residential and commercial environments. With a commitment to quality and innovation, Goodman continues to be a leader in the HVAC market.