Goodman Mfg GKS9 service manual Furnace Specifications, Model

Models: GKS9

1 14
Download 14 pages 61.79 Kb
Page 11
Image 11

FURNACE SPECIFICATIONS

 

 

 

 

 

 

 

MODEL

GKS9

GKS9

GKS9

GKS9

GKS9

GKS9

0453BX*

0703BX*

0704CX*

0904CX*

0905DX*

1155DX*

 

 

 

 

 

 

 

 

Btuh

 

 

 

 

 

 

Input (US)

46,000

69,000

69,000

92,000

92,000

115,000

Output (US)

42,800

64,400

63,900

86,000

86,000

106,500

Input (CAN)

46,000

69,000

69,000

92,000

92,000

115,000

Output (CAN)

42,800

64,400

63,900

86,000

85,300

106,500

A.F.U.E.

92.1%

92.1%

92.1%

92.1%

92.1%

92.1%

 

 

 

 

 

 

 

Rated External Static (" w.c.)

.20 - .50

.20 - .50

.20 - .50

.20 - .50

.20 - .50

.20 - .50

Temperature Rise (°F)

35 - 65

35 - 65

35 - 65

35 - 65

35 - 65

35 - 65

 

 

 

 

 

 

 

ID Blower Pressure Switch Trip Point (" w.c.)

-1.20

-1.10

-1.10

-0.95

-0.75

-1.10

 

 

 

 

 

 

 

Blower Wheel (D" x W")

10 x 8

10 x 8

10 x 10

10 x 10

11 x 10

11 x 10

Blower Horsepower

1/3

1/3

1/2

1/2

3/4

3/4

Blower Speeds

4

4

4

4

4

4

Max CFM @ 0.5 E.S.P.

1200

1200

1600

1600

2000

2000

 

 

 

 

 

 

 

Power Supply

115-60-1

115-60-1

115-60-1

115-60-1

115-60-1

115-60-1

Minimum Circuit Ampacity (MCA)(1)

9.4

9.4

13.8

13.8

13.2

13.2

Maximum Overcurrent Device(2)

15.0

15.0

15.0

15.0

15.0

15.0

Transformer (VA)

40

40

40

40

40

40

 

 

 

 

 

 

 

Primary Limit Setting (°F)

150

160

160

150

160

170

Auxiliary Limit Setting (°F)

150

150

150

150

150

160

Rollout Limit Setting (°F)

200

200

200

200

200

200

 

 

 

 

 

 

 

Fan Delay On Heating

30 secs.

30 secs.

30 secs.

30 secs.

30 secs.

30 secs.

Off Heating

150 secs.

150 secs.

150 secs.

150 secs.

150 secs.

150 secs.

Fan Delay On Cooling

6 sec.

6 sec.

6 sec.

6 sec.

6 sec.

6 sec.

Off Cooling

45 secs.

45 secs.

45 secs.

45 secs.

45 secs.

45 secs.

 

 

 

 

 

 

 

Gas Supply Pressure (Natural/Propane) ("w.c.)

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

7 / 11

Manifold Pressure (Natural/Propane) ("w.c.)

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

3.5 / 10

Orifice Size (Natural/Propane)

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

43 / 55

Number of Burners

2

3

3

4

4

5

 

 

 

 

 

 

 

Vent Connector Diameter (inches) (3)

2

2

2

2

2

2

Combustion Air Connector Diameter (inches) (4)

2

2

2

2

2

2

Shipping Weight (lbs.)

132

135

153

158

170

175

 

 

 

 

 

 

 

(1)Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.

(3)See Installation Instructions for appropriate vent diameter, length and number of elbows.

(4)See Installation Instructions for appropriate combustion air pipe diameter, length and number of elbows.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

1.These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation.

2.For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.

3.The total heat loss from the structure as expressed in TOTAL BTU/HR must be calculated by the manufacturers method or in accordance with the "A.S.H.R.A.E. GUIDE" or "MANUAL J-LOAD CALCULATIONS" published by the AIR CONDITIONING CONTRACTORS OF AMERICA. The total heat loss calculated should be equal to or less than the heating capacity. Output based on D.O.E. test procedures, steady state efficiency times output.

4.Minimum Circuit Ampacity calculated as: (1.25 x Circulator Blower Amps) + I.D. Blower Amps.

Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.

11

Page 11
Image 11
Goodman Mfg GKS9 service manual Furnace Specifications, Model