GPG13(48,60)3A WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

HIGH VOLTAGE!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

 

 

 

 

 

 

 

 

UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

 

 

 

 

 

 

 

 

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

 

 

SUPPLY VOLTAGE

 

 

L2

 

 

 

 

L3

COMPONENT LEGEND

FACTORY WIRING

 

 

 

 

208-230/3/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALS

AUXILLARY LIMIT SWITCH

LINE VOLTAGE

 

 

 

 

CH

NOTE 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMP

COMPRESSOR

LOW VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

C

 

 

 

 

 

 

 

CM

CONDENSER MOTOR

OPTIONAL HIGH VOLTAGE

C

T1

 

 

T2

 

L2

 

 

 

 

 

C

CONTACTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

T1 COMP

T3

 

 

 

 

 

 

 

 

L3

CH

CRANKCASE HEATER

FIELD WIRING

 

 

 

 

 

T3

C

 

 

 

 

 

EM

EVAPORATOR MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

F

FUSE

HIGH VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FC

CM

 

 

 

 

 

 

 

 

FC

FAN CAPACITOR

LOW VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

FS

FLAME SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

EQUIPMENT GROUND

WIRE CODE

 

L

 

N

 

 

 

 

 

 

VMR

 

 

 

GV

GAS VALVE

BK

BLACK

 

 

EM

 

 

 

 

 

 

 

 

 

 

IIC

INTEGRATED IGNITION CONTROL

 

 

 

 

 

 

 

VM

 

2

4

 

 

BL

BLUE

 

 

 

 

 

SEE NOTE 2

 

 

 

 

 

IGN

IGNITOR

BR

BROWN

 

 

 

 

 

 

 

 

 

 

 

 

 

LS

LIMIT SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

GR

GREEN

 

 

 

 

3

2

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLF

FEMALE PLUG/CONNECTOR

OR

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR

 

 

 

 

 

 

 

PS

PRESSURE SWITCH

PK

PINK

 

 

 

 

 

 

 

 

 

 

 

 

 

RS

ROLLOUT SWITCH

NOTE 7

 

 

 

 

 

 

 

NOTE 7

 

 

L2

PU

PURPLE

L1

 

 

 

 

 

IGN

 

 

 

 

 

IIC

TR

TRANSFORMER

RD

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VM

VENT MOTOR

WH WHITE

 

 

 

 

FS

 

 

FS

T5

 

 

 

 

F

 

 

 

 

 

 

 

 

 

VMR

VENT MOTOR RELAY

YL

YELLOW

 

 

C

 

 

 

 

T4

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

EM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

 

 

 

NOTES

 

 

 

 

 

 

 

 

 

 

 

T2

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

 

1

 

3

 

 

 

 

 

1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF

 

4

 

 

 

 

LS

VMR

 

 

 

 

 

 

INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).

 

 

 

 

 

 

 

 

 

 

 

 

2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALS

RS

 

 

 

 

 

 

 

FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

 

 

IIC

 

3

 

 

GV

 

 

 

 

 

3. CRANKCASE HEATER NOT SUPPLIED ON ALL UNITS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PS

 

 

 

 

 

 

 

 

SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED AT MOTOR T1, T2 AND T3 TERMINALS.

 

 

 

ECON

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING SPEED (YELLOW WIRE)

HEATING SPEED (WHITE WIRE)

9

7

 

10

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T4 - LOW SPEED

T1 - LOW SPEED

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

T5 - HIGH SPEED

T2 - MED. SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T3 - HIGH SPEED

 

 

 

 

 

 

 

 

 

NOTE

 

6

5

4

5. ACCESSORY ECONOMIZER PLUG (ON SELECT MODELS) ADJACENT

 

 

 

 

 

 

 

 

5

PLF

TO BLOWER HOUSING IN RETURN AIR COMPARMENT.

 

 

 

 

 

 

 

 

 

 

 

3

2

1

6. USE COOPER CONDUCTORS ONLY.

 

 

R

G

 

W

Y1

Y2

Y

C

 

 

 

 

 

 

 

 

 

 

USE NEC CLASS 2 WIRE.

 

 

 

 

 

 

 

 

 

 

 

 

TO THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

7. L1 AND L2 ON ICC CONTROL IS 24V INPUT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208-230/3/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLER/SERVICEMAN

 

 

 

 

 

 

THERMOSTAT FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

 

 

 

 

 

 

 

 

 

 

 

2 STAGE COOLING

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

NO ECONOMIZER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STATUS LIGHT

EQUIP. STATUS

CHECK

 

 

 

 

 

 

 

 

 

 

W

 

 

WH

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WH

 

 

 

 

 

ON

NORMAL OPERATION

-

 

 

 

 

 

 

 

 

 

GR

 

 

 

 

 

 

 

 

G

 

 

GR

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

OFF

NO POWER OR

CHECK INPUT POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERNAL CONTROL

CHECK FUSE ON CONTROL

 

 

 

 

 

 

 

 

 

 

R

 

 

RD

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAULT

REPLACE CONTROL

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 BLINK

IGNITION FAILURE

GAS FLOW

 

 

YL

 

 

 

 

 

 

 

Y

 

 

PU

 

 

 

 

 

 

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR

GAS PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y2

 

OPEN ROLLOUT

GAS VALVE

 

 

BL

 

 

 

 

 

 

 

C

 

 

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

FLAME SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

C

 

OR

FLAME ROLLOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN AUX. LIMIT

BAD SWITCH

 

WITH ECONOMIZER OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

AUX. LIMIT OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 BLINKS

PRESSURE SWITCH

CHECK

 

 

WH

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

PRESSURE SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 BLINKS

PRESSURE SWITCH CLOSED

CHECK

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITHOUT INDUCER ON

PRESSURE SWITCH

 

 

GR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 BLINKS

OPEN LIMIT SWITCH

MAIN LIMIT OPEN

 

 

RD

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAD SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 BLINKS

FALSE FLAME SENSED

STICKING GAS VALVE

 

 

PU

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 BLINKS

COMPRESSOR

3 MIN. COMP.

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

0140G00087

 

OUTPUT DELAY

ANTI-CYCLE TIMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

30

Page 30
Image 30
Goodman Mfg GPG13 installation manual 0140G00087

GPG13 specifications

Goodman Manufacturing is a prominent name in the HVAC industry, known for providing high-quality heating and cooling systems. Among their diverse lineup, the Goodman GPG13 stands out as a reliable packaged gas/electric unit. This model is particularly designed for residential and light commercial applications, ensuring a perfect blend of efficiency, comfort, and affordability.

One of the primary features of the Goodman GPG13 is its energy efficiency. The unit has a Seasonal Energy Efficiency Ratio (SEER) rating that helps homeowners reduce their energy costs while providing optimal cooling performance during warmer months. With a cooling capacity ranging from 2.5 to 5 tons, it effectively meets the cooling requirements of various sizes of homes or commercial spaces.

The Goodman GPG13 employs advanced technology to guarantee reliable operation. Its quiet operation is a significant advantage, thanks to the sound-dampening design of the unit’s compressor and fan. Moreover, the unit is equipped with a high-efficiency scroll compressor, which is known for its durability and consistent performance. This technology not only enhances the unit’s longevity but also ensures that homeowners enjoy a peaceful indoor environment.

In terms of construction, the Goodman GPG13 is built to last. The unit features a heavy-gauge galvanized steel cabinet with a powder-coated finish, which protects it from the elements and corrosion. This sturdy design ensures that the GPG13 can withstand various environmental conditions without compromising performance. Additionally, it has an easy-access control panel, simplifying maintenance and servicing tasks.

Another noteworthy characteristic of the Goodman GPG13 is its environmentally friendly refrigerant, R-410A. Unlike older refrigerants, R-410A has a lower environmental impact and contributes to ozone layer protection. This focus on environmental responsibility is essential in today’s green-conscious society and reflects Goodman’s commitment to sustainable practices.

The GPG13 is also equipped with a reliable multi-speed blower motor that enhances comfort by providing consistent airflow throughout the space. This capability allows homeowners to maintain desired temperatures while maximizing energy savings.

Overall, the Goodman GPG13 packaged gas/electric unit is an excellent choice for those seeking efficiency, durability, and comfort in their heating and cooling systems. With its range of advanced features and technologies, it stands as a testament to Goodman Manufacturing's dedication to quality and customer satisfaction in HVAC solutions.