Y/Y2 C R Y1 W G

LOW VOLTAGE CONNECTOR

 

18-B18099

400A-83-1068

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

L2

 

 

K4

 

 

 

 

 

 

 

L2

 

 

K3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNUSED

 

 

 

L2

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

MODEL

1068-400

 

K2

 

 

DI

 

 

 

 

SYSTEM

 

R

K1

 

FS

 

 

 

 

 

AUTOMATICIGNITION

 

 

 

9

 

6

 

 

 

MAX.

12

12 12

9 6

3

 

 

 

 

3

 

9

6

 

 

50/60Hz400mA

Y

11

8 5

3

Z21.20

W

11

11

8

5

 

2

2

 

10

10

7 4

P1 1

2

1

ANSI 24VAC

G

10

7 7

4

4

1

 

 

 

F1

 

 

 

 

 

ECON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSE 3 AMP MAX

 

 

 

 

120

 

FORTWOSTAGE

 

 

 

 

P3

 

 

 

135

 

 

 

 

 

 

 

 

 

150

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

SPEED-UP

 

BREAK

 

 

 

 

 

 

P2

 

T2

 

 

 

 

 

 

 

 

 

 

 

 

C22

 

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note:Junction box location shown is optional and is for illustration purposes only.

JUNCTION BOX

Electrical Power Directly To Junction Box

Low Voltage Wiring-*PG1360***1A Only

Refer to the unit wiring diagram for electrical connections. When installed, the unit must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code, ANSI/NFPA No. 70, and/or the CSA C22.1 Electrical Code. Ensure low voltage connections are waterproof.

WARNING

TO AVOID THE RISK OF ELECTRICAL SHOCK, WIRING TO THE UNIT MUST BE POLARIZED AND GROUNDED.

CAUTION

TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY DUE TO FIRE, USE ONLY COPPER CONDUCTORS.

CAUTION

TO PREVENT IMPROPER AND DANGEROUS OPERATION DUE TO WIRING ERRORS, LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. VERIFY PROPER OPERATION AFTER SERVICING.

For unit protection, use a fuse or HACR circuit breaker that is in excess of the circuit ampacity, but less than or equal to the maximum overcurrent protection device. DO NOT EXCEED THE MAXIMUM OVERCURRENT DEVICE SIZE SHOWN ON UNIT DATA PLATE.

All line voltage connections must be made through weatherproof fittings. All exterior power supply and ground wiring must be in approved weatherproof conduit. Low voltage wiring from the unit control panel to the thermostat requires coded cable. See below for ground level and rooftop wiring.

Electrical Power Routed Through Bottom of Unit

Typical Electrical Wiring Unit Voltage

UNIT VOLTAGE

The unit transformer is factory connected for 230V operation. If the unit is to operate on 208V, reconnect the transformer primary lead as shown on the unit wiring diagram. The induced draft blower on some models is equipped with a 230V lead (red) and a 208V lead (black). If equipped, connect the induced draft blower 208V lead (black) in place of the 230V lead (red). Tape the unused 230V lead.

HEAT ANTICIPATOR SETTING

The heat anticipator is to be set by measuring the load (amperage) at the “R” circuit. Follow the instructions provided by the thermostat for more details.

G

Y

R

W

R

From W

Unit Y

G

Typical Thermostat and Unit 24 V Wiring Hookup

9

Page 9
Image 9
Goodman Mfg GPG13 installation manual Typical Thermostat and Unit 24 V Wiring Hookup, Y2 C R Y1 W G

GPG13 specifications

Goodman Manufacturing is a prominent name in the HVAC industry, known for providing high-quality heating and cooling systems. Among their diverse lineup, the Goodman GPG13 stands out as a reliable packaged gas/electric unit. This model is particularly designed for residential and light commercial applications, ensuring a perfect blend of efficiency, comfort, and affordability.

One of the primary features of the Goodman GPG13 is its energy efficiency. The unit has a Seasonal Energy Efficiency Ratio (SEER) rating that helps homeowners reduce their energy costs while providing optimal cooling performance during warmer months. With a cooling capacity ranging from 2.5 to 5 tons, it effectively meets the cooling requirements of various sizes of homes or commercial spaces.

The Goodman GPG13 employs advanced technology to guarantee reliable operation. Its quiet operation is a significant advantage, thanks to the sound-dampening design of the unit’s compressor and fan. Moreover, the unit is equipped with a high-efficiency scroll compressor, which is known for its durability and consistent performance. This technology not only enhances the unit’s longevity but also ensures that homeowners enjoy a peaceful indoor environment.

In terms of construction, the Goodman GPG13 is built to last. The unit features a heavy-gauge galvanized steel cabinet with a powder-coated finish, which protects it from the elements and corrosion. This sturdy design ensures that the GPG13 can withstand various environmental conditions without compromising performance. Additionally, it has an easy-access control panel, simplifying maintenance and servicing tasks.

Another noteworthy characteristic of the Goodman GPG13 is its environmentally friendly refrigerant, R-410A. Unlike older refrigerants, R-410A has a lower environmental impact and contributes to ozone layer protection. This focus on environmental responsibility is essential in today’s green-conscious society and reflects Goodman’s commitment to sustainable practices.

The GPG13 is also equipped with a reliable multi-speed blower motor that enhances comfort by providing consistent airflow throughout the space. This capability allows homeowners to maintain desired temperatures while maximizing energy savings.

Overall, the Goodman GPG13 packaged gas/electric unit is an excellent choice for those seeking efficiency, durability, and comfort in their heating and cooling systems. With its range of advanced features and technologies, it stands as a testament to Goodman Manufacturing's dedication to quality and customer satisfaction in HVAC solutions.