WIRING DIAGRAMS
OUTDOOR CONTROL BOX | ALT. DOUBLE | ||
POLE CONTACTOR | |||
|
| ||
|
| PU | |
C | R | T1 T2 |
R
| OUTDOOR POWER SUPPLY |
| CRANKCASE HEATER |
C L2 | L1 C |
| F |
|
|
|
|
| HERM | Y | Y |
| BK |
|
|
|
| BK | |
|
|
| BR |
| |
| COMPRESSOR/FAN | R |
|
| |
| CAPACITOR |
|
|
| T1 |
|
|
| Y |
|
|
|
|
|
| PU | L1 |
|
|
|
|
| |
| START ASSIST |
|
|
| |
| FAN MOTOR |
|
|
|
|
| Y |
|
|
| PU |
| (START ASSIST |
|
| ||
| IF USED) |
|
|
|
|
COMPRESSOR | PU |
|
|
|
|
| BK BR |
|
|
|
|
C | S |
|
| BK |
|
|
|
|
|
BK
Y
PU
R
R
BK
BK
BK
CRANKCASE HEATER IF USED |
|
| ||
| FACTORY | FIELD | WIRING FOR | |
WIRING CODE | FACTORY | |||
WIRING | WIRING | |||
| OPTIONS | |||
|
|
|
HIGH VOLTAGE
LOW VOLTAGE
WIRE NUT
OPTIONAL START ASSIST
| R | L1 | L2 |
R |
|
|
|
T2 |
| OUTDOOR POWER | |
|
| SUPPLY - (SEE |
|
| UNIT RATING | |
| PLATE) | |
L2 | USE COPPER | |
CONDUCTORS ONLY | ||
| ||
| USE L1 FOR | |
| NEUTRAL OR | |
| GROUNDED SUPPLY | |
| IF USED | |
| EQUIPMENT GROUND |
CONNECT TO APPROP.
CONTROL CIRCUIT HAVING
MIN. 40 VA 24 VOLT
N.E.C. CLASS 2
TRANSFORMER OR FOR
CERTIFIED C.S.A.
INSTALLATION. USE C.S.A.
CERTIFIED ENERGY LIMITED
CLASS 2 TRANSFORMER.
COLOR CODE
BK BLACK
R RED
Y YELLOW
BL BLUE
PU PURPLE
LTBL LIGHT BLUE
BR BROWN
G GREEN
O |
|
|
| (IF USED) |
| O |
N |
|
|
|
|
| N |
T |
| R |
|
|
| T |
A |
|
|
|
|
| A |
C |
|
|
|
|
| C |
T |
|
|
|
|
| T |
O | T2 | COMPRESSOR |
| C | T1 | O |
R |
| MOTOR |
|
|
| R |
|
|
| COMPRESSOR |
|
| |
|
| S | INTERNAL |
|
| |
|
| OVERLOAD |
|
| ||
|
|
|
|
| ||
|
| START ASSIST |
|
|
|
|
|
| (IF USED) |
|
|
|
|
|
|
| CAPACITOR | FAN MOTOR |
| |
|
|
|
|
| ||
|
|
|
|
| CONTACTOR |
|
|
| ON |
|
| COIL |
|
|
| THERMOSTAT |
| G |
|
|
|
| FAN SWITCH |
|
|
| |
|
|
|
|
|
| |
|
| AUTO |
|
|
|
|
|
| THERMOSTAT |
|
|
|
|
|
| COOL |
| FAN RELAY |
| |
|
| ANTICIPATOR |
|
| ||
|
|
| Y | COIL |
| |
|
|
|
|
| ||
|
| R | COOL |
|
|
|
|
|
|
|
|
| |
|
|
|
| THERMOSTAT |
| |
|
| THERMOSTAT | OFF | SYSTEM |
|
|
|
|
|
|
| ||
|
| BULB |
| SWITCH |
|
|
|
|
| HEAT |
| COIL |
|
|
| THERMOSTAT |
|
|
| |
|
| ADJ. HEAT |
| W |
|
|
|
| ANTICIPATOR |
|
|
| |
|
| 24V |
|
|
| |
R |
|
|
| C |
| |
|
|
|
|
| ||
|
|
|
| LOW VOLTAGE |
| |
|
|
|
| TRANSFORMER |
|
NOTES:
REPLACEMENT WIRE MUST BE SAME GAGE AND INSULATION THICKNESS, 105° C APPLIANCE WIRING MATERIAL.
INDOOR POWER SUPPLY |
|
3/98 REV. A |
SINGLE PHASE
R V | BR |
FC
POWER SUPPLY (SEE RATING PLATE)
USE COPPER CONDUCTORS ONLY
|
| BL | HP |
|
| Y | |
|
|
| V |
|
| BR |
|
|
| V | Y |
|
| R |
|
|
| BK |
|
|
| BK |
|
V BL |
| R | CONNECT TO APPROP. CONTROL CIRCUIT HAVING |
|
| Y | MIN. 40 VA. 24 VOLT N.E.C. CALSS 2 |
|
|
| TRAMSFORMER OR FOR CERTIFIED C.S.A |
T1 | T2 | T3 | INSTALLATION. USE C.S.A. CERTIFIED ENERGY |
|
|
| LIMITED CLASS 2 TRANSFORMER. |
C |
|
|
|
L1 | L2 | L3 | EQUIPMENT GROUND USE |
|
|
|
COPPER CONDUCTORS ONLY
BK
BK
|
| OUTDOOR POWER SUPPLY |
|
| ||
|
|
|
| CH |
|
|
| L3 | L2 |
|
| L1 | L1 |
C | C |
|
| C |
| C |
| T3 | T2 |
|
| T1 | T1 |
|
| 2 |
|
|
|
|
| 3 | COMP | 1 | CAP |
|
|
|
|
|
| MOTOR |
|
|
MAIN
V
AUX
Y | S |
ON |
|
|
THERMOSTAT |
|
|
FAN SWITCH | G | CONTACTOR |
AUTO |
| |
| COIL |
HP
CM
BR
BK
THERMOSTAT |
|
COOL |
|
ANTICIPATOR | FAN RELAY |
Y | |
| COIL |
IO
BK
BK
CH
| BK | C | COMP | R |
| R |
|
|
|
COMPONENT CODE |
|
|
| |
CM | OUTDOOR FAN MOTOR |
| ||
COMP | COMPRESSOR |
|
| |
C | CONTACTOR |
|
| |
DC | DEFROST CONTROL |
| ||
LDVR | LOW VOLTAGE DEFROST RELAY | |||
CH | CRANKCASE HEATER |
|
COLOR CODE
BK BLACK
R RED
| COOL |
| |
R |
|
| |
THERMOSTAT |
| THERMOSTAT | |
OFF | SYSTEM | ||
BULB | |||
|
| SWITCH | |
| HEAT |
| |
THERMOSTAT |
| COIL | |
ADJ. HEAT |
| W | |
ANTICIPATOR | 24V |
|
R
LOW VOLTAGE
TRANSFORMER
INDOOR POWER SUPPLY
C
WIRING CODE
FACTORY WIRING | FIELD WIRING |
HIGH VOLTAGE
LOW VOLTAGE
WIRE NUT
LINE SPLICE
IO | INTERNAL OVERLOAD |
LP | LOW PRESSURE CONTROL |
HP | HIGH PRESSURE CONTROL |
OT | OUTDOOR THERMOSTAT (OPTIONAL) |
FC | FAN CAPACITOR |
DFT | DEFROST THERMOSTAT |
RVC | REVERSING VALVE COIL |
HVDR | HIGH VOLTAGE DEFROST RELAY |
CONTROLS SHOWN WITH UTILITIES IN 'ON'POSITION AND THERMOSTAT IN 'OFF' POSITION.
Y YELLOW
BL BLUE
V VIOLET
LTBL | LIGHT BLUE |
BR BROWN
G GREEN
O ORANGE
W WHITE
USE N.E.C. CLASS 2 WIRE
NOTES:
1)TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT.
2)SEE INDOOR UNIT &
OUTDOOR UNIT INSTALLATION
INSTRUCTIONS FOR CONNECTION
OF OPTIONAL OUTDOOR THERMOSTAT.
07/97 REV. D |
THREE PHASE
7 | 06/04 | |
|