MISCELLANEOUS

CONDENSATETRAPANDDRAINSYSTEM(QUALIFIEDSERVICER ONLY)

Annually inspect the drain tubes, drain trap, and field-supplied drain line for proper condensate drainage. Check drain system for hose connection tightness, blockage, and leaks. Clean or repair as necessary.

FLAMESENSOR(QUALIFIEDSERVICERONLY)

Under some conditions, the fuel or air supply can create a nearly invisible coating on the flame sensor. This coating acts as an insulator causing a drop in the flame sense signal. If the flame sense signal drops too low the furnace will not sense flame and will lock out. The flame sensor should be carefully cleaned by a qualified servicer using emery cloth or steel wool. Following clean- ing, the flame sense signal should be as indicated in the Specifica- tions Sheet.

FLUEPASSAGES(QUALIFIEDSERVICERONLY)

The heat exchanger flue passageways should be inspected at the beginning of each heating season. If necessary, clean the pas- sageways as outlined below.

1.TurnOFFtheelectricalpowerandgassupplytothe furnace.

2.Disconnect the gas line and remove the burner/ manifold assembly by removing the screws securing the assembly to the partition panel.

3.Disconnect the flue pipe system from the induced draft blower.

4.Remove the induced draft blower, drain and pressure tap hoses from the recuperator coil front cover.

5.Remove the recuperator coil front cover to expose the coil tubes and turbulators.

6.Remove the recuperator coil turbulators individually by slowly pulling each turbulator forward firmly.

7.Clean the recuperator coil tubes using a long handle wire brush, such as a gun cleaning brush.

8.Clean the primary heat exchanger tubes using a wire brush attached to a length of high grade stainless steel cable, such as drain cleanout cable. Attach a variable speed reversible drill to the other end of the cable. Slowly rotate the cable with the drill and insert it into one of the heat exchanger tubes. While reversing the drill, work the cable in and out several times to obtain sufficient cleaning. Repeat for each tube.

9.Clean residue from furnace using a vacuum cleaner.

10.Replace the parts removed in the previous steps in reverse order.

11.Turn on electrical power and gas to furnace. Check for leaks and proper unit operation.

12.Severe heat exchanger fouling is an indication of an operational problem. Perform the checks listed in Startup Procedure and Adjustments to reduce the chances of repeated fouling.

BEFORE LEAVING AN INSTALLATION

Cycle the furnace with the thermostat at least three times. Verify cooling and fan only operation.

Review the Owner’s Manual with the homeowner and discuss proper furnace operation and maintenance.

Leave literature packet near furnace.

REPAIR AND REPLACEMENT PARTS

When ordering any of the listed functional parts, be sure to provide the furnace model, manufacturing, and serial numbers with the order.

Although only functional parts are shown in the parts list, all sheet metal parts, doors, etc. may be ordered by description.

Parts are available from your distributor.

Functional Parts List-

 

Gas Valve

Blower Motor

Gas Manifold

Blower Wheel

Natural Gas Orifice

Blower Mounting Bracket

Propane Gas Orifice

Blower Cutoff

Igniter

Blower Housing

Flame Sensor

Inductor

Rollout Limit Switch

Heat Exchanger with

Primary Limit Switch

Recuperator Coil

Auxiliary Limit Switch

Coil Front Cover

Pressure Switch

Integrated Control Module

Induced Draft Blower

Transformer

Door Switch

 

51

Page 51
Image 51
Goodman Mfg CVC9/95, MVC95 Miscellaneous, Before Leaving AN Installation, Repair and Replacement Parts

MVC95, CVC9/95 specifications

Goodman Manufacturing has established itself as a leader in the HVAC industry, and among its stellar lineup, the Goodman CVC9/95 and MVC95 stand out for their remarkable features, technologies, and efficiency.

The Goodman CVC9/95 is a high-performance gas furnace, designed for homeowners seeking reliability and cost-effective heating solutions. It operates with an impressive 95% Annual Fuel Utilization Efficiency (AFUE), which means that a significant portion of the fuel it consumes is converted into heat. This level of efficiency not only contributes to lower energy bills but also reduces greenhouse gas emissions, making it an environmentally friendly choice.

One of the standout features of the CVC9/95 is its multi-speed ECM blower motor. This technology adjusts the airflow according to the heating demands of the home, ensuring consistent and comfortable temperatures. The ECM motor also operates quietly, enhancing the comfort of your living space without the disruptive noise often associated with traditional furnaces.

The MVC95, on the other hand, offers similar efficiency with its also 95% AFUE rating. This model is equipped with a patented ignition system that enhances reliability with minimal maintenance needs. Its durable construction includes a heavy-gauge steel cabinet and an insulated blower compartment that minimizes heat loss. This design not only supports optimal performance but also contributes to its longevity.

Both models come with a self-diagnostic control board that provides straightforward troubleshooting capabilities, making it easier for technicians to ensure that your system is operating at peak performance. This feature aids in timely maintenance, which is crucial for extending the lifespan of the unit.

Additionally, Goodman backs their products with a strong warranty, offering a lifetime limited warranty on the heat exchanger and a 10-year limited parts warranty. This assurance provides homeowners peace of mind regarding their investment.

In the landscape of HVAC solutions, the Goodman CVC9/95 and MVC95 models exemplify a commitment to quality, efficiency, and advanced technology. Whether for new constructions or replacements, these furnaces offer superior heating performance coupled with modern conveniences, making them an invaluable choice for homeowners seeking effective climate control solutions. With their low emissions and high efficiency, choosing Goodman means investing in both comfort and sustainability.