12

 

 

 

 

BTU OUTPUT vs TEMPERATURE RISE CHART

 

 

 

BLOWER

100

 

 

 

 

 

 

 

 

 

 

 

90

 

 

600 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE DATA

 

 

 

 

 

700

 

 

 

 

 

 

 

 

80

 

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

900

 

 

 

 

 

 

TEMPERATURE RISE

70

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

1100

 

 

 

 

 

 

60

 

 

 

 

1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

50

 

 

 

 

 

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1800

 

 

 

 

 

 

 

 

 

 

 

2000

 

 

 

 

 

40

 

 

 

 

 

 

2200

 

 

 

 

 

 

 

 

 

 

 

 

 

2400 CFM

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

FORMULAS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BTU OUTPUT = CFM x 1.08 x RISE

 

 

20

 

 

 

 

 

 

 

RISE =

BTU OUTPUT

÷ CFM

 

 

 

 

 

 

 

 

 

 

1.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

30

40

50

60

70

80

90

100

110

120

130

140

150

 

 

 

 

 

 

OUTPUT BTU/HR x 1000

 

 

 

 

 

Page 12
Image 12
Goodman Mfg R-410A service manual Performance Data, Formulas

R-410A specifications

Goodman Manufacturing, a well-respected name in the HVAC industry, has made significant advancements with their R-410A refrigerant technology. R-410A, a hydrofluorocarbon (HFC), has positioned itself as a superior alternative to the older R-22 refrigerant, which has been phased out due to its ozone-depleting properties. Goodman’s commitment to energy efficiency and environmental sustainability is well reflected in their use of R-410A in their air conditioning and heat pump systems.

One of the main features of Goodman’s R-410A systems is their exceptional energy efficiency. The R-410A refrigerant operates at a higher pressure than R-22, which allows for better heat transfer and improved cooling capacity. This results in reduced energy consumption and lower utility bills for consumers. Goodman’s air conditioning units designed for use with R-410A are often rated with high Seasonal Energy Efficiency Ratio (SEER) ratings, making them an eco-friendly choice for residential and commercial applications.

Another notable technology employed by Goodman is their commitment to reliable performance through advanced compressor designs. Goodman's scroll compressors are optimized for R-410A, ensuring quieter operation and reducing vibration levels. These compressors are known for their efficiency and longevity, making them a favorite among homeowners seeking dependable and durable climate control solutions.

Goodman's multi-stage cooling systems that utilize R-410A offer precise temperature control and enhanced comfort. By controlling the speed of the compressor, Goodman’s units can adjust output according to the heating or cooling demand, maximizing comfort while minimizing energy waste. This adaptability not only enhances indoor air quality but also contributes to a greener environment by using less energy.

Furthermore, Goodman incorporates high-tech diagnostic controls into their systems. These controls provide real-time performance data, allowing homeowners and technicians to monitor system status and troubleshoot issues more easily. By using R-410A combined with these innovative technologies, Goodman emphasizes reliability and user-friendly operation.

In conclusion, Goodman Manufacturing’s use of R-410A refrigerant reflects their dedication to efficiency, reliability, and environmental stewardship in HVAC solutions. The combination of advanced compressor technologies, high energy efficiency, and innovative controls solidifies Goodman’s reputation as a leader in the industry, offering homeowners and businesses the comfort and peace of mind they deserve.