Goodman Mfg RT6332013r1 GPH1348-60M41, Heating Performance Data, Expanded Performance Data

Models: RT6332013r1

1 28
Download 28 pages 52.43 Kb
Page 26
Image 26

HEATING PERFORMANCE DATA

 

 

 

 

GPH13[48-60]M41*

MODEL: GPH1348M41*

 

EXPANDED PERFORMANCE DATA

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

 

-5

-10

 

 

MBh

57.2

54.1

51.0

47.6

45.5

44.1

41.0

37.8

32.8

30.2

27.8

26.3

25.3

22.7

20.1

17.6

15.0

12.3

 

 

Delta T

30.8

29.1

27.4

25.6

24.5

23.7

22.0

20.3

17.6

16.3

15.0

14.2

13.6

12.2

10.8

9.5

8.1

6.6

 

 

KW

3.90

3.83

3.75

3.68

3.63

3.60

3.53

3.46

2.48

2.43

2.38

2.36

2.34

2.29

2.24

2.19

2.14

2.09

 

 

AMPS

19.0

17.7

16.7

15.8

15.3

15.0

14.3

13.7

13.1

12.6

12.1

11.9

11.8

11.2

10.6

10.1

9.5

8.7

 

 

COP

4.29

4.14

3.97

3.79

3.66

3.58

3.39

3.20

3.86

3.64

3.42

3.27

3.17

2.91

2.63

2.35

2.05

1.72

 

 

EER

14.7

14.1

13.6

13.0

12.5

12.2

11.6

10.9

13.2

12.4

11.7

11.2

10.8

9.9

9.0

8.0

7.0

5.9

 

 

HI PR

372

357

343

328

320

314

302

290

278

265

255

249

244

235

226

217

209

202

 

 

LO PR

130

121

113

104

98

95

87

77

70

62

55

51

49

42

36

30

26

21

 

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

MODEL: GPH1360M41*

 

 

 

 

 

 

 

 

 

 

 

 

HEATING OPERATION

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

65

60

55

50

47

45

40

35

30

25

20

17

15

10

5

 

-5

-10

 

MBh

69.8

66.0

62.2

58.1

55.5

53.8

50.0

46.1

39.1

36.1

33.3

31.4

30.3

27.1

24.1

21.0

17.9

14.7

 

Delta T

35.9

34.0

32.0

29.9

28.5

27.7

25.7

23.7

20.1

18.6

17.1

16.2

15.6

14.0

12.4

10.8

9.2

7.5

 

KW

4.80

4.71

4.62

4.53

4.47

4.44

4.35

4.26

2.41

2.36

2.32

2.30

2.28

2.24

2.20

2.16

2.12

2.08

 

AMPS

24.1

22.5

21.2

20.1

19.4

19.1

18.1

17.3

16.7

16.0

15.4

15.0

14.9

14.2

13.4

12.8

12.0

11.0

 

COP

4.25

4.10

3.94

3.76

3.63

3.55

3.36

3.17

4.76

4.47

4.19

4.00

3.88

3.54

3.20

2.84

2.47

2.06

 

EER

14.5

14.0

13.5

12.8

12.4

12.1

11.5

10.8

16.3

15.3

14.3

13.7

13.2

12.1

10.9

9.7

8.4

7.1

 

HI PR

385

369

354

339

331

325

312

300

287

274

263

257

252

243

233

224

216

208

 

LO PR

134

124

116

107

101

97

89

80

72

64

56

52

50

43

37

31

27

21

Above information is for nominal CFM and 70 degree indoor dry bulb. Instantaneous capacity listed.

PERFORMANCE TEST

All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor air cubic feet per minute (CFM) as listed in the Performance Data Sheets:

If conditions vary from this, results will change as follows:

1.As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low and high side pressures and power will not change.

2.As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will occur in low and high side pressures and power.

A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown. A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.

A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.

A properly operating unit should be within plus or minus 3 Amps of the typical value shown.

26

Page 26
Image 26
Goodman Mfg RT6332013r1 service manual GPH1348-60M41, Heating Performance Data, Expanded Performance Data, Performance Test