Product Specifications
Specifications
GME8
0703BXC*
GME8
0905CXC*
GME8
1155CXC*
Performance Data
Input¹ | 70,000 | 90,000 | 115,000 |
|
|
|
|
Output¹ | 56,000 | 72,000 | 92,000 |
|
|
|
|
LP Output¹ | 48,000 | 64,000 | 80,000 |
|
|
|
|
AFUE² | 80 | 80 | 80 |
|
|
|
|
Tons AC @ 0.5” ESP | 3 | 5 | 5 |
|
|
|
|
Temperature Rise Range (°F) | 20 - 50 | 35 - 65 | 35 - 65 |
|
|
|
|
Circulator Blower |
|
|
|
|
|
|
|
Size (D x W) | 10 X 8 | 10 X 10 | 10 X 10 |
|
|
|
|
HP | 1/2 | 1 | 1 |
|
|
|
|
Speed | 4 | 4 | 4 |
|
|
|
|
Vent Diameter³ | 4 | 4 | 4 |
|
|
|
|
No. of Burners | 3 | 4 | 5 |
|
|
|
|
Disposable Filter (in²) | 290 | 480 | 480 |
|
|
|
|
Electrical Data |
|
|
|
|
|
|
|
Min. Circuit Ampacity⁴ | 8.2 | 14.8 | 14.8 |
|
|
|
|
Max. Overcurrent Protection⁵ | 15 | 15 | 15 |
|
|
|
|
Ship Weight (lbs) | 130 | 163 | 167 |
|
|
|
|
¹Natural Gas BTU/h: for altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level.
²DOE AFUE based upon Isolated Combustion System (ICS).
³Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in
Canada).
4Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in ac- cordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
5Refers to maximum recommended fuse or circuit breaker size; may use fuses or
Notes
•All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.
•Gas Service Connection ½” FPT
•Important: It is required to size overcurrent protection device and wires properly and make electrical connections in ac- cordance with the National Electrical Code and/or all existing local codes.
www.goodmanmfg.com | 3 |