Wiring Diagram with |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
| WARNING:DISCONNECT POWER BEFORE |
|
|
|
|
|
|
|
|
|
|
| HUMIDIFIER |
| INTEGRATED |
| ||||||||||||||
|
| SERVICING.WIRING TO UNIT MUST BE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONTROL MODULE | |||||||||
|
| PROPERLY POLARIZED AND GROUNDED. |
|
|
|
|
|
|
|
|
| XFMR (6) | GND |
|
|
| |||||||||||||||
|
|
| 24 VAC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| GND (8) |
|
| C2 |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MVC (9) |
|
| GAS |
| ||||||||
|
|
| HUMIDIFIER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HI |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MVH (12) |
| VALVE |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MVL (2) |
|
| M1 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
|
|
| ID BLOWER |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUXILIARY |
| PRESSURE |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24V |
|
|
|
|
|
|
| LIMIT CONTROLS |
| SWITCH |
| |
|
|
| C | G | R | W |
| Y |
|
|
|
| LY |
|
|
|
|
| G |
|
|
|
|
|
|
|
|
| NO |
| |
|
|
|
|
|
|
|
|
|
|
|
| D |
|
|
|
|
|
| PS (10) |
|
|
| C |
| |||||||
|
|
|
|
|
|
|
|
|
|
| STG |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| AUTO |
| 5 MIN | D |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| 2N |
|
|
|
|
|
|
|
| THERMOSTAT CONNECTIONS |
|
| PSO (4) |
|
|
|
|
| |||||||
|
|
|
|
|
| 1 STG |
| 2 STG | MODE |
|
|
|
|
| Y | TO |
|
|
|
|
| ||||||||||
|
|
|
|
|
| 150 SEC | 100 SEC | H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
| TO |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| FF |
|
|
|
|
|
|
| MICRO | HLI (7) |
|
|
|
|
|
| |||||
|
| 10 | 11 | 12 |
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
| WH |
|
|
| LY |
|
|
|
|
| W |
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 7 | 8 | 9 |
|
|
|
|
|
| BL |
|
|
|
|
|
|
| HLO (1) |
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
| 4 | 5 | 6 |
| FUSE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| AUTO RESET |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| R |
|
|
|
|
|
|
|
|
|
| |||
|
| 1 | 2 | 3 |
|
|
|
|
|
|
| LED |
|
|
|
|
|
|
|
|
|
|
|
|
|
| PRIMARY |
| |||
|
|
|
|
|
|
|
| SEE NOTE 6 |
|
|
|
|
|
|
|
|
| RO2 (11) |
|
| LIMIT |
| |||||||||
|
|
|
|
|
|
|
|
|
|
| DIAGNOSTIC |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
| BR |
|
|
|
|
| AUXILIARY |
|
|
|
|
|
|
|
|
|
|
| CONTROL |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| LIMITS |
|
|
| RO1 (5) |
|
|
|
|
| ||||||||
|
|
|
|
|
| INTEGRATED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MANUAL RESET ROLLOUT |
|
| |||||||
|
|
|
|
| CONTROL MODULE |
|
|
| HI |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LIMIT CONTROL(S) |
|
|
| ||
|
|
|
|
|
|
|
| FS |
|
|
|
|
|
|
|
|
|
|
| XFMR (3) | (SINGLE CONTROL ON SOME MODELS) |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24 VAC |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
RD | RD |
|
|
|
| BL |
|
|
|
|
|
|
|
| BR |
|
|
|
|
|
|
|
|
|
|
|
| 40 VA |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TRANSFORMER |
| ||||||
| PU |
|
|
| RD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| LINE NEUTRAL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 115 VAC |
|
| ||||
|
|
| 2 |
|
|
| OR |
|
|
| LO |
|
|
|
|
|
|
|
|
|
|
|
|
|
| FLAME SENSOR |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
YL YL |
| 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| FP |
|
|
|
|
| HOT SURFACE |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| IGNITER |
|
|
| |
|
| WH |
|
|
|
|
|
|
|
|
|
|
|
|
| IGN |
|
|
|
|
|
|
| INTEGRATED CONTROL MODULE | |||||||
PU |
|
|
|
|
|
|
|
|
|
| PARK |
|
|
| BK (HI) BL (MED HI) OR(MED) RD (MED LOW) |
| INTEGRATED CONTROL MODULE |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| WH |
|
|
|
|
|
|
|
|
| ID |
|
| |||||
|
|
|
|
|
|
|
|
| BK |
|
|
| (N) |
|
| IND |
|
|
|
|
|
| BLWR | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| YL(LOW) CIRCULATOR BLOWER |
|
|
| H |
| L |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E |
| O |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| A |
|
|
|
| |||||||
|
|
| BK |
|
| 24V |
|
|
|
|
|
|
|
|
|
|
|
|
|
| T |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| - |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
| BR |
|
|
|
|
|
|
|
| H |
|
|
| ||||||||
|
|
|
|
|
| 115V |
|
|
|
| BL |
|
|
| CIRCULATOR |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLWR | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| I |
|
|
| |||||||||||||
|
|
|
|
|
| XFMR |
|
|
|
|
|
|
|
| H |
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| T |
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| WH |
|
|
| E |
|
|
|
|
|
|
| ||||||||
|
| WH |
|
|
|
|
|
|
|
|
|
|
| H |
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
| BK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ELECTRONIC |
|
|
| |||
|
|
| GR |
|
|
|
|
|
|
|
|
|
| 15 PIN PLUG |
|
|
|
|
|
| AIR CLEANER |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ON SOME MODELS |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BLOWER COMPARTMENT |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BURNER COMPARTMENT |
|
|
|
|
|
|
|
| JUNCTION BOX |
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| WH | BK |
|
|
|
|
| DOOR SWITCH |
|
|
|
|
|
| 24 VAC |
|
|
| DOOR |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| HUMIDIFIER |
|
| SWITCH |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| SWITCH LOCATED IN BLOWER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| COMPARTMENT ON SOME MODELS |
|
| NO | C |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| RD |
|
|
| RD |
|
|
| OR |
|
|
|
|
|
| WARNING: |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DISCONNECT POWER |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DISCONNECT |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| YL | PRESSURE | YL |
|
|
|
|
|
|
|
| ||||||
| WH | WH |
|
|
|
|
|
|
|
|
|
|
|
| BEFORE SERVICING. |
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| PRIMARY LIMIT |
|
|
|
|
|
| SWITCH |
| WIRING TO UNIT |
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| RD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
| YL |
|
|
|
|
|
|
|
|
|
| MUST BE |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PROPERLY |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| YL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| POLARIZED |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| WH |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BK |
| AND GROUNDED. |
|
|
|
|
| L | GND | N |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| BR |
| BL |
|
|
|
|
|
|
|
| TO 115VAC/ 1 |
|
|
| Ø /60 HZ POWER SUPPLY WITH |
| ||||||
|
|
|
|
|
|
|
|
|
|
| WH |
|
|
|
|
|
|
| OVERCURRENT PROTECTION DEVICE |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| BK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| PM | C | HI |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| JUNCTION |
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
| 1 | 2 |
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| HOT |
|
|
|
|
|
|
|
| WH |
|
|
|
| BOX |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| SURFACE |
| 2 STAGE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| IGNITER |
| GAS VALVE |
|
|
|
|
|
|
|
|
|
|
|
| GND |
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| PU |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LINE H |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
INDUCED DRAFT
|
|
| BLOWER | TO 115 VAC/ 1/60HZ |
|
|
|
| |
PU | PU | FLAME |
| POWER SUPPLY WITH |
|
|
| OVERCURRENT PROTECTION | |
|
| SENSOR |
| |
| ROLLOUT LIMITS |
| DEVICE | |
|
|
| ||
|
|
|
| |
| (SINGLE CONTROL ON SOME MODELS) |
|
|
|
Product Specifications
| power death. ⚡ | |
| Multiple | injury, or |
| servicing or installing this unit. | cause property damage, personal |
| before | so may |
| High Voltage: Disconnect all power | sources may be present. Failure to do |
|
| |
| WARNING | |
| ⚠ | |
Always or the wiring. |
0 | STEADY ON = NORMAL OPERATION | |
| OFF = CONTROL FAILURE | |
1 | 1 FLASH = | SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) |
2 | 2 FLASHES = PRESSURE SWITCH STUCK CLOSED | |
3 | 3 FLASHES = PRESSURE SWITCH STUCK OPEN | |
4 | 4 FLASHES = OPEN HIGH LIMIT | |
5 | 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE | |
6 | 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE | |
7 | 7 FLASHES = LOW FLAME SIGNAL | |
8 | 8 FLASHES = CHECK IGNITER OR IMPROPER GROUND |
C RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND
LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNCTION TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION
EQUIPMENT GND FIELD GND FIELD SPLICE SWITCH (TEMP.) IGNITER
SWITCH (PRESS.)
OVERCURRENT PROT. DEVICE
change. | diagram | |
Wiring is subject to | refer to the wiring | unit for the most up |
|
| NOTES: | |
COLOR CODES: | PK PINK | 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. | |
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. | |||
YL YELLOW | BR BROWN | ||
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH | |||
OR ORANGE | WH WHITE | WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY. | |
PU PURPLE | BL BLUE | 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO | |
PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR | |||
GR GREEN | GY GRAY | ||
FLOW CHART) | |||
BK BLACK | RD RED | 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. | |
|
| 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS | |
|
| WHILE IN STANDBY(NO THERMOSTAT INPUTS). | |
0140F00643 REV. A | |||
|
www.goodmanmfg.com | 7 |