Product Specifications
Wiring Diagram — GPH1348-60M43A*
|
| PU |
|
|
| SEE NOTE 3 |
|
| BL |
|
| LPS | BK |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
| 1 | 2 | 3 |
| PU |
|
| BK |
|
|
|
| RD | T3 | L3 |
| ||||
| YL/PK | C | 208 | 240 |
| PU | 2 | |||
|
|
|
|
| BL |
|
| |||
| YL/PK |
|
|
| BL |
|
| |||
|
| 24V |
| RD | T2 | L2 |
| 0 | ||
YL |
|
|
|
|
| 8 | ||||
| BL |
|
|
| YL |
| C | SEE NOTE 5 | ||
|
|
| BL |
| - | |||||
|
| BL |
|
| BK | T1 | L1 |
| 2 | |
| YL |
|
|
|
| BK |
|
| PU | 4 |
|
|
|
|
|
|
| 0 | |||
|
|
|
|
|
|
|
|
| BK | |
|
| BL |
|
|
|
|
|
| / | |
BK |
|
|
| RD | PU |
|
|
| 3 | |
| PU |
|
|
|
|
| GND | / | ||
GR |
|
| GR |
| GR | GR | ||||
|
|
|
|
| 60 | |||||
|
|
|
|
|
|
|
|
| YL |
|
|
|
| Y | Y | C C | C |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| OR |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
PU |
|
| DC |
| CNT | PU | RD |
|
|
|
| ||
|
| PS2 |
|
| O |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| RD | BR |
|
|
| ||
|
|
|
|
|
|
| BK |
|
|
| |||
|
|
| CCR | LVDR |
| WH |
|
|
|
| |||
|
|
|
| W |
|
| WH |
|
| ||||
|
|
|
|
|
|
|
| RD |
|
|
| ||
|
|
|
|
|
|
| R |
| BL |
|
|
| |
BL |
| YL |
|
|
|
| BK |
| PLF |
|
| ||
|
|
|
|
| R |
|
|
|
| ||||
|
|
|
|
|
| WH |
| 3 | 6 | 9 | |||
|
|
|
| HVDR |
|
|
| ||||||
GR |
|
|
|
|
| FC |
|
|
| ||||
|
| DF2 | DF1 |
|
|
|
|
| |||||
|
|
|
|
|
|
| 2 | 5 | 8 | ||||
|
|
|
| DFT |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| RD |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 1 | 4 | 7 | |
|
|
|
|
|
|
|
|
| RD |
| |||
|
|
|
|
| PU |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| RD |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| PU |
|
|
|
|
|
| WH |
|
|
|
|
|
| YL |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| CONTROL | BL/PK |
|
| |
|
|
|
|
| GR | RD RD |
| BOX | BL/PK |
|
|
| |
C | L | G N |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||
1 | 2 | 3 | 4 | 5 |
|
|
|
|
|
|
|
|
|
|
|
|
| EM |
|
| DFT | BKBK |
| HPS |
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| RVC |
|
|
|
|
| ||
SEE NOTE 2 |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| |||
L1 |
|
|
|
|
|
|
|
| L2 | L3 |
|
|
|
|
| PU RD | OR | RD |
| 3 | 6 |
|
| |
|
|
|
|
| OR | YL | 2 | 5 |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| PU | 1 | 4 |
|
|
|
|
|
|
| PU | YL |
|
|
|
|
WH |
| GR |
|
| LVJB | T |
| |||
|
|
|
|
|
|
| A | |||
|
|
|
|
|
|
| H | |||
|
|
|
|
|
| YL |
| Y/Y2 | ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| RD |
| R | E |
|
|
|
|
|
|
| GR |
| G | R |
|
|
|
|
|
|
| WH |
| W1 | M |
|
|
|
|
|
|
|
| O |
| ||
|
|
|
|
|
| OR |
| O |
| |
| BR |
|
|
|
|
| S |
| ||
|
|
|
|
| BR |
| W2 |
| ||
|
|
|
|
|
| T |
| |||
|
|
|
|
|
| BL |
| C |
| |
|
|
|
|
|
|
| A |
| ||
|
|
|
|
|
| PU |
| Y |
| |
|
|
|
|
|
|
| T |
| ||
|
| YL |
|
|
|
| ++ |
| ||
| BR |
|
|
|
|
|
|
| ||
|
|
|
| BK |
|
|
|
|
| |
PU | BK |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SEE |
|
|
|
|
|
|
|
|
|
| NOTE 6 | |
|
|
| RD |
| PU |
|
|
|
| |
PU | BR BK | YL | BK |
|
|
|
|
|
|
|
|
|
|
| RD | RD |
|
| |||
|
|
|
|
|
|
|
| |||
|
|
| S C R |
|
| CHS |
| BK | ||
|
|
|
|
|
| CH | ||||
| CM |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| BK |
|
|
| |
|
|
|
|
|
|
|
| GR |
| |
|
|
| COMP | SEE NOTE 6 |
|
| ||||
|
|
|
|
|
|
|
|
|
SUPPLY VOLTAGE
C |
| T2 | T2 C | ||
T1 |
|
|
| ||
T1 COMP |
|
|
| ||
|
| C |
|
| |
|
| T3 |
|
| HVDR |
|
|
| F |
|
|
|
|
|
|
| CM |
|
|
| T3 | C |
|
|
|
|
|
| |
|
|
| SEE NOTE 6 |
| |
|
| CHS |
|
|
|
| SEE NOTE 2 | N |
| CH | |
L | EM |
|
|
| |
3 |
|
|
| ||
|
|
|
|
| |
1 | G | 2 |
|
|
|
|
|
|
| ||
|
| SEE NOTE 3 |
|
| |
|
| 2 |
|
| |
|
| 1 |
| 3 | |
|
|
|
| ||
|
|
|
|
| TR |
COMPONENT LEGEND
C | CONTACTOR |
CCR | COMPRESSOR CONTACTOR RELAY |
CH | CRANKCASE HEATER |
CHS | CRANKCASE HEATER SW ITCH |
CM | CONDENSER MOTOR |
COMP | COMPRESSOR |
DC | DEFROST CONTROL |
DFT | DEFROST THERMOSTAT |
EM | EVAPORATOR MOTOR |
GND | EQUIPMENT GROUND |
HVDR | HIGH VOLTAGE DEFROST RELAY |
LPS | LOW PRESSURE SW ITCH |
LVDR | LOW VOLTAGE DEFROST RELAY |
LVJB | LOW VOLTAGE JUNCTION BOX |
PLF | FEMALE PLUG / CONNECTOR |
RVC | REVERSING VAVLE COIL |
TR | TRANSFORMER |
HPS | HIGH PRESSURE SWITCH |
NOTES: |
|
FACTORY WIRING
LINE VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
| WIRE CODE |
BK | BLACK |
BL | BLUE |
BR | BROW N |
GR | GREEN |
OR | ORANGE |
PU | PURPLE |
RD | RED |
WH | WHITE |
YL | YELLOW |
power death. ⚡ | |
Multiple | injury, or |
all power before servicing or installing this unit. | Failure to do so may cause property damage, personal |
Disconnect | be present. |
High Voltage: | sources may |
| |
Warning | |
⚠ | |
the . |
|
|
|
|
| 24V |
| DFT |
|
| |
|
|
|
|
|
|
|
|
| ||
| RVC |
| DFT |
| ||||||
R | R |
| C | |||||||
|
|
| DC |
|
|
|
| |||
|
| O |
|
|
|
|
|
|
| |
|
| W |
| Y | PS2 |
| CNT | |||
3 | 6 |
|
|
| HPS | LPS |
|
|
| |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |
2 | 5 |
|
|
|
|
| 2 | 3 |
|
|
1 | 4 |
|
|
|
|
|
|
| ||
|
|
|
|
| 1 EM | C |
|
| ||
| 4 |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
| 5 |
|
|
|
|
|
|
|
|
|
| 6 |
|
|
|
|
|
|
| SEE NOTE 2 | |
| PLF |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| C |
| ||
|
|
|
|
|
|
|
|
| ||
|
| R | W2 | O | W1 Y/Y2 | G | C | Y1 |
|
|
|
|
| THERMOSTAT |
|
|
|
|
|
1.REPLACEMENT W IRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2.TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM"2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3 FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE W IRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4.START ASSIST FACTORY EQUIPPED WHEN REQUIRED
5.USE COPPER CONDUCTORS ONLY
++ USE N.E.C. CLASS 2 WIRE
6.CRANKCASE HEATER AND CRANKCASE HEATER SWITCH FACTORY INSTALLED OPTION.
7.ECONOMIZER PLUG LOACTED IN THE RETURN AIR COMPARTMENT. REMOVE MALE PLUG, ATTACH FEMALE PLUG TO THE ECONOMIZER ACCESSORY.
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
Wiring is subject to change. Always refer to the wiring diagram or unit for the most |
www.goodmanmfg.com | 15 |