JAI TM-6710 operation manual Camera Timing Charts

Models: TM-6710

1 42
Download 42 pages 60.04 Kb
Page 31
Image 31

Page 25

Camera Timing Charts

4 Camera Timing Charts

Model: TM-6710/6710CL

Operation Mode: 60 Frames/Second

Master Clock: 50.98_MHz, M= 19.62_ nsec

Pixel Clock: 12.75_MHz, P= 78.46_ nsec

1. Pixel Clock and Digital Data

Pixel Clock

A

B

Data

Tcd

Tdc

Thd

Tcd: Clock to Data Ready

Tdc: Data Ready to Next Clock

Thd: Data Hold Time

Tcd = 6.7_nsec, Tdc = 71.7_nsec, Thd= 2.3_ nsec.

2. Horizontal Signals

fHD = [ 15.24 KHz]

 

 

 

 

 

tHD = [ 65.6 msec]

 

 

 

 

 

 

 

 

External HD

 

 

 

 

 

 

 

 

 

 

 

A [8p], (0.619msec)

 

Internal HD

B [759 P], (59.6msec)

 

 

C [836 P], (65.6msec)

 

LDV

D [142 P], (11.2msec)

 

E [694 P], (54.4msec)

 

 

 

G [1 P], (0.08msec)

F [836 P], (65.6msec)

 

H [148 P], (11.61msec)

 

 

 

Digital Data

 

 

 

I [648 P], (50.8msec)

J [40 P], (3.14msec)

 

 

Analog Video

 

 

N [25 P], (0.96msec)

K [648 P], ( 25.4msec)

M [56 P], (2.2msec)

 

 

 

 

J [168 P], 6.59msec)

K [20 P], (0.784msec)

 

 

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Page 31
Image 31
JAI TM-6710 operation manual Camera Timing Charts