Page 14

Operation

Internal Fast Reset Mode

Internal Slow Reset Mode

Mode 0:

Normal Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Async Mode 1-4:

Fast Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Async Mode: 5-8:

Slow Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

Async Mode 9:

External pulse width control mode

3.3.3 (a) External Pulse Width Control Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

The TM-6710 can be reset with external reset pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(VINIT). Set the dial switch to “9.” Apply a pulse-

 

 

 

 

 

 

 

 

 

 

 

 

 

width control VINIT signal generated from an external

(VINIT)

 

 

 

 

 

 

100

 

 

event trigger to the camera. The internal reset pulse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R2

will be latched to Hd and at 5th HD timing from the

 

 

 

 

 

 

 

 

 

 

 

4.7k R1

external pulse leading edge (negative going edge). The

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CCD discharge pulse will be generated to clear the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VINIT Input Schematic

images. The internal VINIT will be generated at the

 

 

following edge (positive going edge) of the external

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pulse, resetting the internal timing including the video sync. The shutter speed is the same as the external pulse width, but the integration delays 5H from the leading edge. For the immediate reset option, please contact PULNiX.

FIGURE 10. External Pulse Width Mode

External

Pulse

Width

VINIT

Hd

Internal VINIT

Min 1.5H

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3H

Transfer Gate Pulse

Discharge pulse

6H

7 H X Exposure Time

EXPOUT

Exposure Time

 

X

 

 

 

 

 

 

 

Composite

Video

For the progressive format, one frame of video output will start from the rising edge of the pulse width control. At async mode with external pulse input high, the video output will be disabled as the camera continues discharging the CCD image, providing black video only.

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Page 20
Image 20
JAI TM-6710 operation manual External Pulse Width Control Mode, Vinit Input Schematic