Page 13

Operation

3.3.2 External Synchronization

 

 

 

 

The TM-6710 can take external HD and VD for

 

 

 

 

 

 

 

 

 

 

phase locking. The internal PLL will take external

OUTSIDE

INSIDE CAMERA

 

 

 

 

HD and lock with the CCD HD. (The CCD HD

CAMERA

 

 

 

 

 

1µF

 

frequency is half of the analog video output HD.)

Ext HD

 

 

 

 

 

 

 

 

 

 

 

 

(or Ext VD)

C1

 

Example: Ext. HD = 30.49KHz, VD will be 120Hz

 

4.7k

R1

 

 

 

 

 

and Master Clock will be 50.98MHz.

 

 

 

 

 

 

External Sync Input Schematic

 

The internal sync generator will take external VD to

generate internal VD. External VD frequency should be the same as the frame rate.

3.3.3Asynchronous Reset with Shutter

To activate the asynchronous reset mode, use the Mode control switch on the back panel of the camera (TM-6710). The asynchronous trigger input (VINIT) is applied to pin #6 of the 12-pin connector (TM- 6710) or pins #9 and #22 of the Camera Link connector (TM-6710CL).

The TM-6710’s asynchronous reset is flexible and takes external HD for phase

 

locking. Applying a VINIT pulse resets the camera’s scanning and purging of

0

1

 

9

 

the CCD. When async reset pulse (VINIT) is applied to High state (+5V) with

8

2

 

dial switch select from 1 to 9, the TM-6710’s asynchronous camera discharges

7

3

 

the photo charges into the substrate drain although the camera is still running on

6

4

 

its sync timing and only outputs captured video. When the negative going reset

5

 

 

 

 

 

pulse is applied, the camera will latch the falling edge to its next horizontal

Shutter Control Switch

 

drive and reset vertical sync timing immediately. Then it starts integrating for

 

 

 

the period of shutter control set by either an external pulse width pulse or internal shutter control.

 

Therefore the horizontal phase will not be interrupted. The TM-6710 asynchronous camera will output

 

one frame of shuttered video after reset.

 

 

 

 

TABLE 1.

Shutter Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set

 

Manual Mode

 

Async Reset Mode

 

 

 

 

 

 

 

 

 

 

 

 

0

 

No Shutter (1/120)

 

No Shutter (1/120)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1/250

 

128H

1/32,000

1.0H

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

1/500

 

64H

1/16,000

2.0H

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

1/1,000

 

32H

1/12,000

3.0H

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

1/2,000

 

16H

1/8,000

4.0H

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

1/4,000

 

8.0H

1/4,000

8.0H

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

1/8,000

 

4.0H

1/2,000

16H

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

1/12,000

 

3.0H

1/1,000

32H

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

1/16,000

 

2.0H

1/500

64H

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

1/32,000

 

1.0H

Shutter determined by pulse width

 

 

 

 

 

 

 

 

 

 

 

There are three modes to control the asynchronous reset and shutter speed:

External Pulse Width Control Mode

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Page 19
Image 19
JAI TM-6710 Operation External Synchronization, Asynchronous Reset with Shutter, External Sync Input Schematic