Page 22

Operation

TABLE 2. RS-232C Control Commands Summary Table

1st CHAR

2nd CHAR

“S”

(Shutter)

“M” (Manual)

 

 

“A” (Async)

“G”

(Gain)

“M” (Main)

 

 

“A” (Fine A CH)

 

 

“B” (Fine B CH)

“V”

(A/D Vref)

“A” (CH1)

 

 

“B” (CH2)

 

 

“T” (Top)

 

 

“L” (BTM/Vsub)

“W”

(Write)

“P” (Page)

 

 

“U” (User)

 

 

“S” (System)

“L”

(Load)

“P” (Page)

 

 

“U” (User)

 

 

“S” (System)

“R”

(Report)

“R” (Current)

 

 

“P” (Page)

 

 

“U” (User)

 

 

“S” (System)

 

 

“X” (Execute)

 

 

“D” (Date)

“C”

(Clock)

“0” (120Hz)

 

 

“1” (60Hz)

“N”

(Partial Scan)

“0” (Normal)

 

 

“1” (200 lines)

 

 

“2” (100 lines)

“O”

(Async sync out)

“0” (Continuous)

 

 

“1” (One Shot)

3rd CHAR

Response

Functions

“0” - “9” Mode

ACK

Manual shutter mode

“0” - “8” Mode

ACK

Async shutter mode

“9” (Pulse width)

ACK

Pulse width mode

“00” - “FF”

ACK

Main CH Gain Control

“00” - “FF”

ACK

CH1 Gain Fine Tuning

“00” - “FF”

ACK

CH2 Gain Fine Tuning

“00” - “FF”

ACK

CH1 Vref Fine Tuning

“00” - “FF”

ACK

CH2 Vref Fine Tuning

“00” - “FF”

ACK

Vtop voltage setting

“00” - “FF”

ACK

Vbottom - Vsub setting

“0” - “6”

ACK

Write to P EPROM

“A” - “D”

ACK

Write to U EPROM

“A” - “D”

ACK

Write to S EPROM

“0” - “6”

ACK

Load from P EPROM

“A” - “D”

ACK

Load from U EPROM

“A” - “D”

ACK

Load from S EPROM

 

ACK

ACK + “RR”+12x2 bytes

“0” - “6”

ACK

ACK + “P”+{“9” - “F”}+ 12x2 bytes

“A” - “D”

ACK

ACK + “U”+{“9” - “F”}+ 5x2 bytes

“A” - “D”

ACK

ACK + “S”+{“9” - “F”}+ 5x2 bytes

 

ACK

Set camera with loaded data

 

DATE

Report program date

 

ACK

Using master clock

 

ACK

Using half of master clock

 

ACK

Normal scan

 

ACK

200 line scan

 

 

100 line scan

 

ACK

Continuous sync out in Async Mode.

 

 

One sync with on VINIT.

TM-6710/6710CL High-Speed Progressive Scanning CCD Camera

Page 28
Image 28
JAI TM-6710 operation manual RS-232C Control Commands Summary Table, 1st Char 2nd Char