3.2.1Mode Control Switches (TM-6710)

Mode

Control Switch

Up/Down Switch

 

0

Normal mode

 

 

1

Gain control (A/B)

up - increase gain of Ch. A

 

 

 

down - decrease gain of Ch. A

2

Gain (A/B) fine tune

up - increase gain of Ch. A

 

 

 

down - decrease gain of Ch. A, while decrease/increase gain of Ch. B,

 

 

at 5:1 ration

 

3

Main Vref control

up - increase gain of Ch. A

 

 

 

down -decrease A/D voltage reference of Ch. A & Ch. B

4

Vref balance control

up - increase gain of Ch. A

 

 

 

down - increase/decrease A/D voltage reference of Ch. A, while

 

 

decrease/increase gain of Ch. B

5

Gain selection

up: 9dB

down: 12dB

6

Gain selection

up: 18dB

down: 22dB

7

Clock selection

up: 120Hz

down: 60Hz

8

Async/Manual shutter

up: Manual

down: Async

9

Factory set recall

up/down - recall only

 

A

Power up (recall or save)

up: recall

down: save

B-C

User page storage (store

up: recall

down: save

 

user settings)

 

 

D

Direct shutter

up - increase manual shutter speed

 

 

down - decrease manual shutter speed

E

Partial scan

up: 100 lines

down:

F

Partial scan

up: normal scan

down: 200 lines

3.3 Modes of Operation

3.3.1Shutter Operation

The TM-6710 has a substrate drain electronic shutter mechanism which provides a superb picture at various speeds without smearing. Manual shutter speed control can be selected at 1/250, 1/500, 1/1,000, 1/2,000, 1/4,000, 1/8,000, 1/16,000 or 1/32,000 sec. rate.

Note: Some slow speed shutter rates will not apply to partial scanning.