Product SPecificationS Product SPecificationS
12 www.goodmanmfg.com SS-GSX13
expAnded Cooling dAtAgSx130361e* / CA*f3636*6d*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
1350
MBh 32.9 34.1 37.4 - 32.2 33.3 36.5 - 31.4 32.5 35.7 - 30.6 31.7 34.8 - 29.1 30.2 33.0 - 27.0 27.9 30.6 -
S/T 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.74 0.51 - 0.89 0.74 0.51 -
∆ T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
kW 2.44 2.49 2.55 - 2.61 2.65 2.73 - 2.75 2.80 2.88 - 2.88 2.94 3.02 - 2.99 3.05 3.14 - 3.08 3.14 3.24 -
/anos 9.7 9.9 10.0 - 10.1 10.3 10.5 - 10.6 10.8 11.0 - 11.0 11.2 11.4 - 11.4 11.6 11.8 - 11.8 12.0 12.2 -
Hi PR 183 197 208 - 205 221 234 - 234 252 266 - 266 286 302 - 299 322 340 - 331 356 376 -
Lo PR 95 101 110 - 100 107 117 - 104 111 121 - 110 117 127 - 115 122 134 - 119 126 138 -
1200
MBh 32.0 33.1 36.3 - 31.2 32.4 35.5 - 30.5 31.6 34.6 - 29.7 30.8 33.8 - 28.2 29.3 32.1 - 26.2 27.1 29.7 -
S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
∆ T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
kW 2.42 2.47 2.54 - 2.59 2.64 2.71 - 2.73 2.78 2.86 - 2.86 2.91 3.00 - 2.96 3.02 3.11 - 3.06 3.12 3.21 -
/anos 9.7 9.8 10.0 - 10.1 10.2 10.4 - 10.6 10.7 10.9 - 11.0 11.1 11.3 - 11.4 11.5 11.8 - 11.8 11.9 12.2 -
Hi PR 181 195 206 - 203 219 231 - 231 249 263 - 264 284 299 - 296 319 337 - 328 353 372 -
Lo PR 94 100 109 - 99 106 116 - 103 110 120 - 109 116 126 - 114 121 132 - 118 125 137 -
1050
MBh 29.5 30.6 33.5 - 28.8 29.9 32.7 - 28.1 29.2 31.9 - 27.4 28.4 31.2 - 26.1 27.0 29.6 - 24.2 25.0 27.4 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
∆ T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 2.37 2.42 2.48 - 2.53 2.58 2.65 - 2.67 2.72 2.80 - 2.79 2.85 2.93 - 2.90 2.96 3.04 - 2.99 3.05 3.14 -
/anos 9.6 9.7 9.8 - 10.0 10.1 10.3 - 10.4 10.5 10.7 - 10.8 10.9 11.1 - 11.2 11.3 11.6 - 11.6 11.7 12.0 -
Hi PR 176 189 200 - 197 212 224 - 224 242 255 - 256 275 291 - 288 309 327 - 318 342 361 -
Lo PR 91 97 106 - 96 103 112 - 100 107 116 - 105 112 122 - 110 117 128 - 114 121 133 -
75
1350
MBh 33.5 34.5 37.3 40.0 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.1 32.1 34.7 37.3 29.6 30.5 33.0 35.4 27.4 28.2 30.5 32.8
S/T 0.88 0.79 0.60 0.38 0.91 0.81 0.62 0.40 0.93 0.84 0.63 0.41 0.96 0.86 0.65 0.42 1.00 0.90 0.68 0.44 1.00 0.90 0.68 0.44
∆ T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 11 19 17 14 10
kW 2.46 2.50 2.57 2.65 2.62 2.67 2.75 2.83 2.77 2.82 2.91 2.99 2.90 2.96 3.04 3.14 3.01 3.07 3.16 3.26 3.10 3.17 3.26 3.36
/anos 9.8 9.9 10.1 10.3 10.2 10.3 10.5 10.7 10.7 10.8 11.0 11.3 11.1 11.2 11.4 11.7 11.5 11.7 11.9 12.2 11.9 12.1 12.3 12.6
Hi PR 185 199 210 219 208 223 236 246 236 254 268 280 269 289 306 319 303 326 344 359 334 360 380 396
Lo PR 96 102 112 119 101 108 118 126 105 112 123 130 111 118 129 137 116 124 135 144 120 128 139 149
1200
MBh 32.5 33.5 36.2 38.9 31.8 32.7 35.4 38.0 31.0 31.9 34.5 37.1 30.2 31.1 33.7 36.2 28.7 29.6 32.0 34.4 26.6 27.4 29.7 31.8
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.65 0.42 0.96 0.86 0.65 0.42
∆ T 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 2.44 2.49 2.56 2.63 2.61 2.66 2.73 2.81 2.75 2.80 2.89 2.97 2.88 2.94 3.02 3.11 2.99 3.05 3.14 3.23 3.08 3.14 3.24 3.34
/anos 9.7 9.9 10.0 10.2 10.1 10.3 10.5 10.7 10.6 10.8 11.0 11.2 11.0 11.2 11.4 11.6 11.4 11.6 11.8 12.1 11.8 12.0 12.2 12.5
Hi PR 183 197 208 217 206 221 234 244 234 252 266 277 266 287 303 316 300 322 340 355 331 356 376 392
Lo PR 95 101 110 118 100 107 117 124 104 111 121 129 110 117 127 136 115 122 134 142 119 127 138 147
1050
MBh 30.0 30.9 33.4 35.9 29.3 30.2 32.7 35.1 28.6 29.5 31.9 34.2 27.9 28.7 31.1 33.4 26.5 27.3 29.6 31.7 24.6 25.3 27.4 29.4
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
∆ T 21 20 16 11 21 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.39 2.43 2.50 2.57 2.55 2.60 2.67 2.75 2.69 2.74 2.82 2.90 2.81 2.87 2.95 3.04 2.92 2.98 3.07 3.16 3.01 3.07 3.16 3.26
/anos 9.6 9.7 9.9 10.1 10.0 10.1 10.3 10.5 10.5 10.6 10.8 11.0 10.8 11.0 11.2 11.4 11.2 11.4 11.6 11.9 11.6 11.8 12.0 12.3
Hi PR 178 191 202 211 199 215 227 236 227 244 258 269 258 278 293 306 291 313 330 344 321 345 365 380
Lo PR 92 98 107 114 97 104 113 121 101 108 118 125 106 113 124 132 112 119 130 138 115 123 134 143
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions