Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
700
MBh 20.2 20.9 22.9 - 19.7 20.4 22.4 - 19.3 20.0 21.9 - 18.8 19.5 21.3 - 17.8 18.5 20.3 - 16.5 17.1 18.8 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.79 0.66 0.46 -
∆ T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 1.60 1.63 1.68 - 1.71 1.75 1.80 - 1.82 1.85 1.91 - 1.91 1.95 2.01 - 1.98 2.02 2.09 - 2.05 2.09 2.16 -
Amps 5.7 5.8 6.0 - 6.1 6.3 6.5 - 6.6 6.8 7.0 - 7.1 7.3 7.5 - 7.6 7.8 8.0 - 8.0 8.2 8.5 -
Hi PR 226 243 257 - 253 273 288 - 288 310 328 - 328 353 373 - 369 398 420 - 408 439 464 -
Lo PR 99 105 115 - 105 111 122 - 109 116 126 - 114 122 133 - 120 127 139 - 124 132 144 -
800
MBh 21.9 22.7 24.8 - 21.4 22.2 24.3 - 20.9 21.6 23.7 - 20.4 21.1 23.1 - 19.3 20.0 22.0 - 17.9 18.6 20.3 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.45 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
∆ T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
kW 1.64 1.67 1.72 - 1.75 1.79 1.85 - 1.86 1.90 1.96 - 1.95 1.99 2.06 - 2.03 2.07 2.14 - 2.10 2.14 2.21 -
Amps 5.8 6.0 6.1 - 6.3 6.4 6.7 - 6.8 7.0 7.2 - 7.3 7.5 7.8 - 7.8 8.0 8.3 - 8.3 8.5 8.8 -
Hi PR 233 251 265 - 261 281 297 - 297 320 338 - 338 364 385 - 381 410 433 - 421 453 478 -
Lo PR 102 109 119 - 108 115 125 - 112 119 130 - 118 125 137 - 124 131 143 - 128 136 148 -
900
MBh 22.5 23.4 25.6 - 22.0 22.8 25.0 - 21.5 22.3 24.4 - 21.0 21.7 23.8 - 19.9 20.6 22.6 - 18.4 19.1 21.0 -
S/T 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.86 0.71 0.49 - 0.86 0.72 0.50 -
∆ T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
kW 1.65 1.68 1.73 - 1.77 1.80 1.86 - 1.87 1.91 1.97 - 1.97 2.01 2.07 - 2.05 2.09 2.16 - 2.12 2.16 2.23 -
Amps 5.9 6.0 6.2 - 6.3 6.5 6.7 - 6.9 7.1 7.3 - 7.4 7.6 7.8 - 7.9 8.1 8.3 - 8.3 8.6 8.8 -
Hi PR 235 253 267 - 264 284 300 - 300 323 341 - 342 368 388 - 385 414 437 - 425 457 483 -
Lo PR 103 110 120 - 109 116 127 - 113 121 132 - 119 127 138 - 125 133 145 - 129 137 150 -
75
700
MBh 20.5 21.1 22.9 24.6 20.1 20.7 22.4 24.0 19.6 20.2 21.8 23.4 19.1 19.7 21.3 22.9 18.2 18.7 20.2 21.7 16.8 17.3 18.7 20.1
S/T 0.79 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.38 0.89 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆ T 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 1.61 1.64 1.69 1.74 1.73 1.76 1.82 1.87 1.83 1.87 1.93 1.99 1.92 1.96 2.02 2.09 2.00 2.04 2.11 2.17 2.07 2.11 2.18 2.25
Amps 5.7 5.8 6.0 6.3 6.2 6.3 6.5 6.8 6.7 6.9 7.1 7.4 7.2 7.4 7.6 7.9 7.6 7.8 8.1 8.4 8.1 8.3 8.6 8.9
Hi PR 228 246 259 270 256 276 291 303 291 313 331 345 332 357 377 393 373 402 424 442 412 444 469 489
Lo PR 100 107 116 124 106 113 123 131 110 117 128 136 116 123 134 143 121 129 141 150 125 133 145 155
800
MBh 22.3 22.9 24.8 26.6 21.7 22.4 24.2 26.0 21.2 21.8 23.6 25.4 20.7 21.3 23.1 24.8 19.7 20.2 21.9 23.5 18.2 18.8 20.3 21.8
S/T 0.81 0.73 0.55 0.35 0.84 0.76 0.57 0.37 0.87 0.77 0.59 0.38 0.89 0.80 0.60 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
∆ T 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 1.65 1.68 1.73 1.78 1.77 1.80 1.86 1.92 1.87 1.91 1.97 2.04 1.97 2.01 2.07 2.14 2.05 2.09 2.16 2.23 2.12 2.16 2.23 2.30
Amps 5.9 6.0 6.2 6.4 6.3 6.5 6.7 7.0 6.9 7.1 7.3 7.6 7.4 7.6 7.8 8.1 7.9 8.1 8.3 8.7 8.3 8.6 8.8 9.2
Hi PR 235 253 267 279 264 284 300 313 300 323 341 356 342 368 389 405 385 414 437 456 425 457 483 504
Lo PR 103 110 120 128 109 116 127 135 113 121 132 140 119 127 138 147 125 133 145 154 129 137 150 160
900
MBh 22.9 23.6 25.5 27.4 22.4 23.0 24.9 26.8 21.9 22.5 24.4 26.1 21.3 22.0 23.8 25.5 20.3 20.9 22.6 24.2 18.8 19.3 20.9 22.4
S/T 0.85 0.76 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.61 0.40 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43
∆ T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 10 19 17 14 10
kW 1.66 1.69 1.75 1.80 1.78 1.82 1.87 1.93 1.89 1.93 1.99 2.05 1.98 2.03 2.09 2.16 2.06 2.11 2.18 2.25 2.13 2.18 2.25 2.32
Amps 5.9 6.1 6.3 6.5 6.4 6.6 6.8 7.0 7.0 7.1 7.4 7.7 7.5 7.6 7.9 8.2 7.9 8.1 8.4 8.7 8.4 8.6 8.9 9.3
Hi PR 238 256 270 282 267 287 303 316 303 326 345 359 345 372 392 409 389 418 442 461 429 462 488 509
Lo PR 104 111 121 129 110 117 128 136 114 122 133 142 120 128 140 149 126 134 146 156 130 139 151 161
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power