PERFORMANCE DATA

Model: SSZ140181A* / CA*F3131*6A*+TXV / MBR800**-1

Conditions: 80° IDB, 67° IWB @ 600 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

 

 

 

 

 

 

75°

 

18,900

13,097

5,803

1,329

80°

 

18,675

13,106

5,569

1,370

85°

 

18,450

13,111

5,339

1,411

90°

 

18,225

13,159

5,066

1,447

95°

 

18,000

13,203

4,797

1,483

100°

 

17,550

13,117

4,433

1,514

105°

 

17,100

13,018

4,082

1,544

110°

 

16,470

12,591

3,879

1,571

115°

 

15,840

12,160

3,680

1,597

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

16,680

13,071

3,609

1,426

Model: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1

Conditions: 80° IDB, 67° IWB @ 850 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

75°

 

25,200

17,861

7,339

1,873

80°

 

24,900

17,873

7,027

1,930

85°

 

24,600

17,879

6,721

1,986

90°

 

24,300

17,946

6,354

2,036

95°

 

24,000

18,005

5,995

2,086

100°

 

23,400

17,888

5,512

2,128

105°

 

22,800

17,753

5,047

2,170

110°

 

21,960

17,171

4,789

2,207

115°

 

21,120

16,583

4,537

2,243

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

22,239

17,825

4,414

2,006

Model: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1

Conditions: 80° IDB, 67° IWB @ 1050 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

75°

 

30,240

22,369

7,871

2,259

80°

 

29,880

22,383

7,497

2,326

85°

 

29,520

22,391

7,129

2,392

90°

 

29,160

22,475

6,685

2,451

95°

 

28,800

22,549

6,251

2,510

100°

 

28,080

22,402

5,678

2,560

105°

 

27,360

22,233

5,127

2,610

110°

 

26,352

21,504

4,848

2,653

115°

 

25,344

20,768

4,576

2,696

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

26,687

22,324

4,364

2,417

Model: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 80° IDB, 67° IWB @ 1400 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

 

 

 

 

 

 

75°

 

42,000

30,603

11,397

3,006

80°

 

41,500

30,623

10,877

3,095

85°

 

41,000

30,634

10,366

3,184

90°

 

40,500

30,748

9,752

3,263

95°

 

40,000

30,850

9,150

3,342

100°

 

39,000

30,649

8,351

3,408

105°

 

38,000

30,418

7,582

3,475

110°

 

36,600

29,420

7,180

3,533

115°

 

35,200

28,413

6,787

3,590

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

37,066

30,542

6,524

3,217

Model: SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1

Conditions: 80° IDB, 67° IWB @ 1050 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

 

 

 

 

 

 

75°

 

36,330

24,713

11,617

2,662

80°

 

35,898

24,729

11,169

2,742

85°

 

35,465

24,738

10,727

2,822

90°

 

35,033

24,830

10,203

2,892

95°

 

34,600

24,912

9,688

2,963

100°

 

33,735

24,749

8,986

3,023

105°

 

32,870

24,563

8,307

3,083

110°

 

31,659

23,757

7,902

3,135

115°

 

30,448

22,944

7,504

3,187

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

32,062

24,663

7,399

2,851

Model: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 80° IDB, 67° IWB @ 1550 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

 

 

 

 

 

 

75°

 

48,300

34,653

13,647

3,382

80°

 

47,725

34,675

13,050

3,483

85°

 

47,150

34,687

12,463

3,585

90°

 

46,575

34,817

11,758

3,674

95°

 

46,000

34,932

11,068

3,764

100°

 

44,850

34,704

10,146

3,840

105°

 

43,700

34,443

9,257

3,916

110°

 

42,090

33,313

8,777

3,981

115°

 

40,480

32,172

8,308

4,047

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

42,625

34,583

8,043

3,621

Model: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1

Conditions: 80° IDB, 67° IWB @ 1850 CFM

Outdoor

 

Total

Sensible

Latent

Total

 

Temp. ° F.

 

Btuh

Btuh

Btuh

Watts

 

 

 

 

 

 

75°

 

59,325

41,430

17,895

4,159

80°

 

58,619

41,457

17,161

4,294

85°

 

57,913

41,472

16,440

4,428

90°

 

57,206

41,626

15,580

4,547

95°

 

56,500

41,764

14,736

4,666

100°

 

55,088

41,492

13,596

4,767

105°

 

53,675

41,180

12,495

4,868

110°

 

51,698

39,829

11,869

4,955

115°

 

49,720

38,465

11,255

5,042

 

TVA Conditons @ 95° OD DB, 75° ID DB, 63° ID WB

 

95°

52,355

41,347

11,008

4,477

21

Page 21
Image 21
Goodman Mfg SSZ 14 SEER service manual Performance Data, 18,000 13,203 797 483

SSZ 14 SEER specifications

Goodman Manufacturing has established a reputation for producing reliable and efficient HVAC systems, and the SSZ 14 SEER model follows this tradition. This ducted heat pump is engineered to offer effective heating and cooling, making it a versatile choice for homeowners looking to maintain comfortable indoor temperatures year-round.

One of the standout features of the Goodman SSZ 14 is its impressive 14 SEER (Seasonal Energy Efficiency Ratio) rating. This efficiency metric indicates that the heat pump can cool a designated space while consuming less energy compared to many standard systems, which translates to potential savings on monthly utility bills. This model is not only cost-effective but also environmentally friendly, as it reduces energy consumption and lowers greenhouse gas emissions.

The Goodman SSZ 14 is equipped with an energy-efficient compressor that enhances its performance. The compressor operates quietly, which maintains a tranquil environment inside the home. Additionally, the sound-dampening features ensure that noise levels are kept to a minimum, providing homeowners with peace of mind while enjoying the comfort of their space.

This model features a durable construction designed to withstand diverse weather conditions. The coil is constructed from corrosion-resistant materials which prolong its lifespan and ensure reliability over time. Furthermore, the unit comes with a factory-installed filter drier that protects the refrigerant system by trapping contaminants and moisture, ensuring optimal operation.

Another key characteristic of the SSZ 14 SEER model is its environmentally responsible refrigerant. Goodman has transitioned to using R-410A refrigerant, which is known for being less harmful to the ozone layer compared to older refrigerants. This not only meets environmental regulations but also aligns with modern energy efficiency standards.

Installation flexibility is another advantage of the Goodman SSZ 14, as it is compatible with various home layouts. The unit can be installed in a range of configurations, making it easy to integrate into both new constructions and existing systems.

In summary, the Goodman Manufacturing SSZ 14 SEER model offers a blend of efficiency, durability, and versatility. With its energy-saving features, quiet operation, and long-lasting design, it stands out in the competitive landscape of heat pumps. Homeowners can trust the Goodman SSZ 14 to deliver comfort while promoting energy conservation and environmental responsibility.