Goodman Mfg SSZ 14 SEER Heating Specifications, Conditions 1400 CFM Indoor Air @ 70F DB, capacity

Models: SSZ 14 SEER

1 28
Download 28 pages 50.9 Kb
Page 25
Image 25
Conditions: 1400 CFM Indoor Air @ 70°F DB

HEATING SPECIFICATIONS

Model: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 1400 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

51.54

4.44

67.92

84.30

100.68

 

117.07

60

48.79

4.28

65.17

81.55

97.94

 

114.32

55

45.92

4.11

62.30

78.68

95.07

 

111.45

50

42.93

3.92

59.31

75.69

92.07

 

108.46

45

39.73

3.70

56.11

72.49

88.88

 

105.26

40

36.90

3.50

53.28

69.66

86.05

 

102.43

35

34.03

3.30

50.41

66.79

83.18

 

99.56

30

34.27

3.26

50.65

67.03

83.41

 

99.79

25

31.63

3.08

48.01

64.39

80.77

 

97.15

20

29.12

2.90

45.50

61.89

78.27

 

94.65

15

26.48

2.70

42.86

59.25

75.63

 

92.01

10

23.76

2.48

40.14

56.52

72.91

 

89.29

5

21.07

2.25

37.45

53.83

70.21

 

86.59

0

18.37

2.01

34.75

51.13

67.52

 

83.90

-5

15.68

1.76

32.06

48.44

64.82

 

81.20

-10

12.84

1.48

29.22

45.61

61.99

 

78.37

Model: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 1550 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

57.82

4.25

74.20

90.59

106.97

 

123.35

60

54.74

4.10

71.12

87.50

103.89

 

120.27

55

51.52

3.94

67.90

84.28

100.67

 

117.05

50

48.16

3.76

64.54

80.93

97.31

 

113.69

45

44.57

3.55

60.96

77.34

93.72

 

110.10

40

41.40

3.36

57.78

74.16

90.55

 

106.93

35

38.18

3.17

54.56

70.94

87.33

 

103.71

30

36.62

2.94

53.00

69.38

85.76

 

102.15

25

33.80

2.77

50.18

66.56

82.94

 

99.32

20

31.12

2.61

47.50

63.89

80.27

 

96.65

15

28.30

2.43

44.68

61.06

77.45

 

93.83

10

25.39

2.24

41.77

58.16

74.54

 

90.92

5

22.51

2.03

38.89

55.28

71.66

 

88.04

0

19.63

1.82

36.01

52.40

68.78

 

85.16

-5

16.75

1.59

33.13

49.52

65.90

 

82.28

-10

13.72

1.34

30.11

46.49

62.87

 

79.25

Model: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1

Conditions: 1850 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

71.65

4.34

88.03

104.41

120.80

 

137.18

60

67.83

4.19

84.21

100.59

116.98

 

133.36

55

63.84

4.03

80.22

96.60

112.99

 

129.37

50

59.68

3.85

76.06

92.44

108.83

 

125.21

45

55.23

3.64

71.62

88.00

104.38

 

120.76

40

51.30

3.45

67.68

84.06

100.45

 

116.83

35

47.31

3.26

63.69

80.07

96.46

 

112.84

30

47.86

3.17

64.24

80.63

97.01

 

113.39

25

44.17

2.99

60.56

76.94

93.32

 

109.70

20

40.68

2.83

57.06

73.44

89.83

 

106.21

15

36.99

2.63

53.37

69.76

86.14

 

102.52

10

33.19

2.43

49.57

65.95

82.34

 

98.72

5

29.42

2.21

45.81

62.19

78.57

 

94.95

0

25.66

1.98

42.04

58.42

74.81

 

91.19

-5

21.90

1.74

38.28

54.66

71.04

 

87.43

-10

17.94

1.46

34.32

50.70

67.09

 

83.47

*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)