0241AJ, 0361AH

CONTROL BOX

DC

CCR

LVJB

 

 

OR

 

O

 

 

 

WH

 

W2

 

RD

 

R

 

 

 

BL/PK

 

Y

OUTDOOR POWER SUPPLY

SEE RATING PLATE

to-date wiring.

-60]1AF,

 

DF2 HVDR

 

 

 

 

 

 

DF1

 

LVDR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PS2

R-PS1 C

BK

BK DFT R-DFT

R

W Y O O-RV CNT C-RV

C

 

 

 

 

 

 

 

RD RD

RD

WH

OR

BK YL BK

BL

 

 

 

 

 

 

 

BL/PK

 

 

YL/PK

 

 

 

 

 

 

 

 

 

 

 

YL/PK

 

 

 

 

 

 

SC

BL

 

C

 

COLOR CODE

BK ---------------

BLACK

BL/PK ----------

BLUE/PINK STRIPE

BR ---------------

BROWN

GR----------------

GREEN

OR ---------------

ORANGE

PU ---------------

PURPLE

RD ---------------

RED

WH --------------

WHITE

YL ---------------

YELLOW

YL/PK---------

YELLOW/PINK STRIPE

L1

POLE CONTACTOR ONLY

ALTERNATE DOUBLE

T1

C

CADM

IO

C

DF1

HVDR

DF2

 

 

 

T2

5 SR 2

1

 

L2

SC

C

 

 

 

 

 

CADM

 

 

 

 

 

 

 

 

H C

A

U

X

S

 

 

 

RCCF

 

 

 

 

 

 

COMP

 

 

 

 

 

 

 

 

 

A

 

 

 

 

F

M

 

 

 

 

 

 

 

I

R

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

SA

 

 

 

CADM

(IF USED)

 

 

 

IO

A

U

X

 

 

 

 

 

 

 

 

 

 

 

 

on the unit for the most up-

WIRING DIAGRAMS SSZ140[18,30,42

HIGH VOLTAGE! BEFOREDISCONNECT ALL POWER SERVICING OR INSTALLING THIS SOURCESUNIT. MULTIPLE POWERMAY BE PRESENT. FAILURE TO DAMAGE,DO SO MAY CAUSE PROPERTY PERSONAL INJURY OR DEATH.

 

 

 

 

 

 

BL BL BK

 

 

RD

RD

 

BL

 

 

 

 

 

 

 

BK

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

T2

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

SR

 

 

 

YL

 

L1

L2

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

C

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL

 

 

 

 

 

 

 

 

 

 

PU

HERM

 

 

 

 

 

 

 

 

 

 

 

 

C

YL

T1

T2

 

 

 

 

 

BR

 

 

RD

F

 

YLYL

 

 

 

 

 

 

 

 

 

RCCF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

L2

 

 

 

 

 

 

 

 

 

SA

 

 

ALTERNATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(IF USED)

 

 

DOUBLE POLE

 

 

BL/PK

BL/PK

 

RD

 

 

 

NOTE 2

RD

 

 

CONTACTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFT

 

RVC

 

HPS

 

 

 

 

CHS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RD BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CH

 

EQUIPMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GROUND

 

 

 

 

 

 

 

COMP

 

 

 

USE COPPER

 

MAIN

 

 

 

 

 

MAIN

 

 

 

CONDUCTORS

 

PU

YL/PK

BK

 

AUX

 

 

 

 

 

ONLY

 

 

 

 

 

 

 

 

 

 

AUX

 

RD

 

 

 

GR

 

 

 

 

BR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IO

BK

YL/PK

LPS

YL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM

 

 

 

 

 

R

 

 

 

 

 

 

 

WIRING CODE

 

 

 

CM

M

 

FACTORY WIRING

 

 

 

 

A

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

I

 

HIGH VOLTAGE

 

 

CH

 

CH

 

 

LOW VOLTAGE

 

 

 

 

 

 

 

S

 

 

 

OPTIONAL HIGH VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIELD WIRING

 

 

 

 

 

 

 

 

HIGH VOLTAGE

 

 

 

 

 

 

 

 

LOW VOLTAGE

R-DFT

DFT

DFT

DC

C

 

 

 

 

COMPONENT CODE

 

 

 

 

 

 

 

R-PS1

 

 

PS2 Y

 

C ---------------

CONTRACTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

CADM-----------

COMFORT ALERT DIAGNOSTIC MODULE

 

LVDR

 

LPS

 

 

 

RVC

CCR------------

COMPRESSOR CONTACTOR RELAY

R

 

 

 

 

O-RV

CH -------------

CRANKCASE HEATER

 

 

 

 

 

 

C-RV

 

 

 

 

 

 

 

 

CHS ------------

CRANKCASE HEATER SWITCH

 

 

O

 

 

 

 

 

CM ------------

OUTDOOR FAN MOTOR

 

W

 

 

 

 

CNT

C

CMR ----------

CONDENSER MOTOR RELAY

 

 

 

 

 

 

C

 

 

 

 

 

 

 

COMP --------

COMPRESSOR

 

 

 

CCR

 

 

 

 

CS -------------

COMPRESSOR SOLENOID

 

 

 

 

 

 

HPS

 

DC -------------

DEFROST CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFT -----------

DEFROST THERMOSTAT

 

 

 

 

 

 

 

 

DT -------------

DISCHARGE THERMOSTAT

R

W2

O

 

Y

 

 

HPS-------------

HIGH PRESSURE SWITCH

 

 

FIELD LOW

HVDR --------

HIGH VOLTAGE DEFROST RELAY

 

 

 

 

 

 

 

}VOLTAGE

IO --------------

INTERNAL OVERLOAD

 

INDOOR POWER SUPPLY

CONNECTI

 

ONS

LPS ------------

LOW PRESSURE SWITCH

 

 

 

 

 

 

 

 

LVDR ---------

LOW VOLTAGE DEFROST RELAY

 

 

 

 

 

 

 

 

LVJB ----------

LOW VOLTAGE JUNCTION BOX

 

 

 

 

 

 

 

 

RCCF ---------

RUN CAPACITOR FOR COMPRESSOR & FAN

 

NOTES:

 

 

 

 

 

 

RVC -----------

REVERSING VALVE COIL

 

1) TO INDOOR UNIT LOW VOLTAGE

 

SA -------------

START ASSIST

 

TERMINAL BLOCK & INDOOR

 

 

THERMOSTAT.

 

 

 

 

 

SC -------------

START CAPACITOR FOR COMPRESSOR

 

2) START ASSIST FACTORY

 

(OPTIONAL)

 

 

EQUIPPED WHEN REQUIRED.

 

START RELAY FOR COMPRESSOR (OPTIONAL)

 

 

 

 

 

 

 

SR -------------

USE N.E.C. CLASS 2 WIRE

CONTROLS SHOWN WITH THERMOSTAT IN 'OFF'

 

 

0140R00171-A

 

POSITION.

 

 

 

 

Wiring is subject to change, always refer to the wiring diagram

28

Page 28
Image 28
Goodman Mfg SSZ 14 SEER service manual 0241AJ, 0361AH, 601AF

SSZ 14 SEER specifications

Goodman Manufacturing has established a reputation for producing reliable and efficient HVAC systems, and the SSZ 14 SEER model follows this tradition. This ducted heat pump is engineered to offer effective heating and cooling, making it a versatile choice for homeowners looking to maintain comfortable indoor temperatures year-round.

One of the standout features of the Goodman SSZ 14 is its impressive 14 SEER (Seasonal Energy Efficiency Ratio) rating. This efficiency metric indicates that the heat pump can cool a designated space while consuming less energy compared to many standard systems, which translates to potential savings on monthly utility bills. This model is not only cost-effective but also environmentally friendly, as it reduces energy consumption and lowers greenhouse gas emissions.

The Goodman SSZ 14 is equipped with an energy-efficient compressor that enhances its performance. The compressor operates quietly, which maintains a tranquil environment inside the home. Additionally, the sound-dampening features ensure that noise levels are kept to a minimum, providing homeowners with peace of mind while enjoying the comfort of their space.

This model features a durable construction designed to withstand diverse weather conditions. The coil is constructed from corrosion-resistant materials which prolong its lifespan and ensure reliability over time. Furthermore, the unit comes with a factory-installed filter drier that protects the refrigerant system by trapping contaminants and moisture, ensuring optimal operation.

Another key characteristic of the SSZ 14 SEER model is its environmentally responsible refrigerant. Goodman has transitioned to using R-410A refrigerant, which is known for being less harmful to the ozone layer compared to older refrigerants. This not only meets environmental regulations but also aligns with modern energy efficiency standards.

Installation flexibility is another advantage of the Goodman SSZ 14, as it is compatible with various home layouts. The unit can be installed in a range of configurations, making it easy to integrate into both new constructions and existing systems.

In summary, the Goodman Manufacturing SSZ 14 SEER model offers a blend of efficiency, durability, and versatility. With its energy-saving features, quiet operation, and long-lasting design, it stands out in the competitive landscape of heat pumps. Homeowners can trust the Goodman SSZ 14 to deliver comfort while promoting energy conservation and environmental responsibility.