Goodman Mfg SSZ 14 SEER service manual Heat Pump Specifications

Models: SSZ 14 SEER

1 28
Download 28 pages 50.9 Kb
Page 5
Image 5
HEAT PUMP SPECIFICATIONS

HEAT PUMP SPECIFICATIONS

SSZ140[18,30, 342,48,60]1AA-AE; SSZ140241AA-AH; SSZ140361AA-AG

Cooling Capacity, BTUH

Compressor

R.L. Amps

L.R. Amps

Low Pressure Switch

Open

Close

High Pressure Switch

Open

Close

Condenser Fan Motor

Horsepower

F.L. Amps

Liquid Line, Inches O.D.*

Suction Line, Inches O.D.* Refrigerant Charge

Power Supply

Minimum Circuit Ampacity(1) Maximum Overcurrent Device(2)

Electrical Conduit Size

Power Supply (Inches)

Approximate Shipping W eight

 

SSZ140181AA-AE

SSZ140241AA-AH

SSZ140301AA-AE

SSZ140361AA-AG

SSZ140421AA-AE

SSZ140481AA-AE

SSZ140601AA-AE

 

 

 

 

 

 

 

 

 

18,000

24,000

30,000

36,0 00

42,000

48,0 00

60,000

 

 

 

 

 

 

 

 

 

8.97

12.82

14.10

16.67

1 7.95

19.87

26.41

 

48.0

58.3

73.0

79.0

1 12.0

109.0

130 .0

 

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

 

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

 

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

 

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

 

 

 

 

 

 

 

 

 

1/12

1/6

1/6

1/4

1/4

1/4

1/4

 

0.6

1.1

1.1

1.5

1.5

1.5

1.5

 

 

 

 

 

 

 

 

 

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

 

3/4"

3/4"

3/4"

7/8"

7/8"

7/8"

7/8"

 

143.0

163.0

188.0

213.0

213.0

273.0

278 .0

 

 

 

 

 

 

 

 

 

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

 

11.80

17.10

18.73

22.40

24.00

26.40

34.60

 

20

25

30

30

40

40

60

 

 

 

 

 

 

 

 

 

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

 

199

207

219

242

242

266

280

 

 

 

 

 

 

 

 

*Up to 24' in equivalent line length

(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.

NOTES:

Always check the S & R plate for electrical data on the unit being installed.

Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).

Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).

Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information.