HEAT PUMP SPECIFICATIONS
SSZ140[18,30,42,48,60]1AF; SSZ140241AJ; SSZ140361AH
Cooling Capacity, BTUH
Compressor
R.L. Amps
L.R. Amps
Low Pressure Switch
Open
Close
High Pressure Switch
Open
Close
Condenser Fan Motor
Horsepower
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.* Refrigerant Charge
Power Supply
Minimum Circuit Ampacity(1) Maximum Overcurrent Device(2)
Electrical Conduit Size
Power Supply (Inches)
Approximate Shipping W eight
SSZ140181AF | SSZ140241AJ | SSZ140301AF | SSZ140361AH | SSZ140421AF | SSZ140481AF | SSZ140601AF |
|
|
|
|
|
|
|
18,000 | 24,000 | 30,000 | 36,000 | 42,000 | 48,000 | 60,000 |
|
|
|
|
|
|
|
9.0 | 12.82 | 14.10 | 16.67 | 17.95 | 19.9 | 26.41 |
48.0 | 58.3 | 73.0 | 79.0 | 112.0 | 109.0 | 130.0 |
22 PSIG | 22 PSIG | 22 PSIG | 22 PSIG | 22 PSIG | 22 PSIG | 22 PSIG |
50 PSIG | 50 PSIG | 50 PSIG | 50 PSIG | 50 PSIG | 50 PSIG | 50 PSIG |
610 PSIG | 610 PSIG | 610 PSIG | 610 PSIG | 610 PSIG | 610 PSIG | 610 PSIG |
420 PSIG | 420 PSIG | 420 PSIG | 420 PSIG | 420 PSIG | 420 PSIG | 420 PSIG |
|
|
|
|
|
|
|
1/12 | 1/6 | 1/6 | 1/4 | 1/4 | 1/4 | 1/4 |
0.6 | 1.1 | 1.0 | 1.5 | 1.5 | 1.5 | 1.5 |
|
|
|
|
|
|
|
3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" |
3/4" | 3/4" | 3/4" | 7/8" | 7/8" | 7/8" | 7/8" |
140.0 | 160.0 | 185.0 | 210.0 | 210.0 | 270.0 | 275.0 |
|
|
|
|
|
|
|
11.90 | 17.10 | 18.60 | 22.40 | 23.90 | 26.40 | 34.50 |
20 | 25 | 30 | 30 | 40 | 40 | 60 |
|
|
|
|
|
|
|
1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 |
199 | 207 | 219 | 242 | 242 | 266 | 280 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Up to 24' in equivalent line length
(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
NOTES:
•Always check the S & R plate for electrical data on the unit being installed.
•Installer will need to supply 7/8" to
•Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).
•Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
•Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT, NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/ circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.