COOLING PERFORMANCE DATA GPH1360H41**

MODEL: GPH1360H41** EXPANDED PERFORMANCE DATA COOL ING OP ERATION

D esign Su bco olin g, 12±3 °F @ the liquid access fittin g co nn ection A H R I 95 test cond it ion s. D esig n Superh eat 8±3 °F @ the compressor suct ion access fitt ing con n ection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering I n door We t Bul b Temper atur e
IDB*Airflow 596367715963677159 63 677159 63 67 715963677159636771
MBh 56.3 58.4 64.0 - 55.0 57.0 62.5 - 53.7 55.7 61.0 - 52.4 54.3 59.5 - 49.8 51.6 56.5 - 46.1 47.8 52.4 -
S/T 0.75 0.62 0.43 - 0.77 0.65 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.86 0.71 0.50 -
Delta T 19 16 12 - 19 1 6 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
2079 KW 3.85 3.93 4.06 - 4.15 4.24 4.37 - 4.41 4.50 4.65 - 4.64 4.74 4.89 - 4.83 4.94 5.10 - 5.00 5.11 5.28 -
AMPS 16.2 16.5 17.0 - 17.4 17.7 18.3 - 18.7 19.1 19.7 - 19.9 20.3 20.9 - 21.0 21.5 22.2 - 22.2 22.7 23.4 -
HI PR 233 250 264 - 261 281 296 - 297 319 337 - 338 364 384 - 380 409 432 - 420 452 477 -
LO PR 107 114 124 - 113 120 131 - 118 125 137 - 124 131 144 - 130 138 150 - 134 143 156 -
MBh 54.7 56.7 62.1 - 53.4 55.4 60.7 - 52.2 54.1 59.2 - 50.9 52.7 57.8 - 48.3 50.1 54.9 - 44.8 46.4 50.9 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
Delta T 19 17 13 - 20 1 7 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
70 1850 KW 3.82 3.90 4.03 - 4.11 4.20 4.34 - 4.37 4.47 4.61 - 4.60 4.70 4.85 - 4.79 4.90 5.06 - 4.96 5.07 5.23 -
AMPS 16.1 16.4 16.9 - 17.2 17.6 18.1 - 18.5 19.0 19.5 - 19.7 20.1 20.7 - 20.8 21.3 22.0 - 22.0 22.5 23.2 -
HI PR 230 248 262 - 258 278 294 - 294 316 334 - 335 360 380 - 376 405 428 - 416 448 473 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 149 - 133 141 154 -
MBh 50.5 52.3 57.3 - 49.3 51.1 56.0 - 48.1 49.9 54.7 - 47.0 48.7 53.3 - 44.6 46.2 50.7 - 41.3 42.8 46.9 -
S/T 0.69 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 -
Delta T 20 17 13 - 20 1 7 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
1621 KW 3.73 3.81 3.93 - 4.02 4.10 4.23 - 4.27 4.36 4.50 - 4.48 4.58 4.73 - 4.67 4.77 4.93 - 4.83 4.94 5.10 -
AMPS 15.7 16.0 16.5 - 16.8 17.2 17.7 - 18.1 18.5 19.0 - 19.2 19.6 20.2 - 20.3 20.8 21.4 - 21.4 21.9 22.6 -
HI PR 223 240 254 - 251 270 285 - 285 307 324 - 325 349 369 - 365 393 415 - 403 434 458 -
LO PR 103 109 120 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
MBh 57.3 59.0 63.9 68.5 56.0 57.6 62.4 66.9 54.6 56.3 60.9 65.3 53.3 54.9 59.4 63.8 50.6 52.1 56.4 60.6 46.9 48.3 52.3 56.1
S/T 0.85 0.76 0.57 0.37 0.88 0.79 0.59 0.38 0.90 0.81 0.61 0.39 0.93 0.83 0.63 0.40 0.97 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T212016112220161122 20 161122 20 17 11 22 20 16 11 20 19 15 11
2079 KW 3.89 3.97 4.09 4.22 4.18 4.27 4.41 4.55 4.44 4.54 4.69 4.84 4.67 4.78 4.93 5.10 4.87 4.98 5.14 5.32 5.04 5.15 5.32 5.50
AMPS 16.3 16.7 17.2 17.7 17.5 17.9 18.4 19.0 18.9 19.3 19.9 20.5 20.0 20.5 21.1 21.8 21.2 21.7 22.3 23.1 22.4 22.9 23.6 24.4
HI PR 235 253 267 278 264 284 300 312 300 323 341 355 341 367 388 405 384 413 436 455 424 457 482 503
LO PR 108 115 126 13 4 114 122 133 141 119 126 13 8 147 125 133 145 154 131 139 152 162 135 144 157 167
MBh 55.6 57.3 62.0 66.5 54.3 55.9 60.6 65.0 53.0 54.6 59.1 63.4 51.8 53.3 57.7 61.9 49.2 50.6 54.8 58.8 45.5 46.9 50.8 54.5
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T222117122321171223 21 171223 21 17 12 22 21 17 12 21 19 16 11
75 1850 KW 3.85 3.94 4.06 4.19 4.15 4.24 4.37 4.51 4.41 4.50 4.65 4.80 4.64 4.74 4.89 5.06 4.83 4.94 5.10 5.27 5.00 5.11 5.28 5.46
AMPS 16.2 16.5 17.0 17.6 17.4 17.7 18.3 18.9 18.7 19.1 19.7 20.4 19.9 20.3 20.9 21.6 21.0 21.5 22.2 22.9 22.2 22.7 23.4 24.2
HI PR 233 250 264 276 261 281 297 309 297 319 337 352 338 364 384 401 380 409 432 451 420 452 477 498
LO PR 107 114 124 13 3 113 120 131 140 118 125 13 7 146 124 131 144 153 130 138 150 160 134 143 156 166
MBh 51.3 52.9 57.2 61.4 50.2 51.6 55.9 60.0 49.0 50.4 54.6 58.6 47.8 49.2 53.2 57.1 45.4 46.7 50.6 54.3 42.0 43.3 46.8 50.3
S/T 0.78 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.76 0.58 0.37 0.89 0.79 0.60 0.39 0.89 0.80 0.61 0.39
Delta T232117122321171223 21 171223 21 17 12 23 21 17 12 21 20 16 11
1621 KW 3.76 3.84 3.96 4.09 4.05 4.13 4.27 4.40 4.30 4.39 4.53 4.68 4.52 4.62 4.77 4.93 4.71 4.81 4.97 5.14 4.87 4.98 5.15 5.32
AMPS 15.8 16.1 16.6 17.2 16.9 17.3 17.8 18.4 18.2 18.6 19.2 19.8 19.4 19.8 20.4 21.1 20.5 20.9 21.6 22.3 21.6 22.1 22.8 23.6
HI PR 226 243 256 267 253 272 288 300 288 310 327 341 328 353 373 389 369 397 419 437 408 439 463 483
LO PR 104 111 121 12 9 110 117 128 136 114 121 13 3 141 120 128 139 148 126 134 146 155 130 138 151 161
* IDB : Entering Indo or Dry Bulb Temperatur e NOTE: Sh aded area is ACCA (TVA) conditions
High and low pr essur es are m easured at t he liqui d and s uction access fittin gs.