Wiring is
CONTROL BOX
DC
|
|
|
| LVJB | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
RD |
| R |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
WH |
| W2 |
| NOTE 1 | |||||||
|
| ||||||||||
OR |
| O |
| ||||||||
|
|
|
|
|
|
|
|
| |||
YL |
| Y |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
BL |
| C |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
OUTDOOR POWER SUPPLY
SEE RATING PLATE
WIRING
subject to change. Always refer to the
DF2
HBK V
LVDR | D | BK |
| R | |
| DF1 | |
|
|
C Y O O W2 R R DFT
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BL |
| OR | WH |
|
| RD |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| RD |
| ||||||||||||||
|
| YL |
| BK |
| RD |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
COLOR CODE
BK | BLACK |
BL | BLUE |
BL/PK | BLUE/PINK STRIP |
BR | BROW N |
OR | ORANGE |
PU | PURPLE |
RD | RED |
WH | WHITE |
YL | YELLOW |
YL/PK | YELLOW/PINK STRIP |
WIRING CODE
FACTORY WIRING
L1
T1
T2
C
IO |
|
|
| T2 | ||
| T1 | COMP | ||||
|
|
|
|
|
| |
|
|
|
|
|
| T3 |
DF1 |
|
|
|
|
|
|
HVDR |
|
|
|
|
|
|
DF2 |
|
|
|
|
|
|
|
| IO |
| A | U | X |
|
|
|
| |||
|
|
|
|
| ||
|
|
| M |
| ||
|
| CM | A | |||
|
|
| I | |||
|
|
|
|
| N |
T3
L2
C
FC
C L3
HIGH VOLTAGE! DISCONNECT ALL UNIT. MULTIPLE DO SO MAYCAUSE |
DIAGRAMS
wiring
BK | BK RD |
| ||
BL |
| BK | RD |
|
BL | T1 | T2 | T3 | YL |
|
|
|
|
HIGH VOLTAGE LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
CH
(IF USED)
POWER POWER |
diagram on the unit for the most
YL | L1 | L2 | L3 |
|
YL | BK | BK | C |
|
|
|
| RD |
|
|
|
| PU |
|
|
|
| FC | BR |
|
|
|
|
RD BK | YL | BK RVC BK | ||
| COMP |
|
|
|
|
|
|
|
T1 | T3 |
| EQUIPMENT GROUND |
| USE COPPER | ||
BR |
|
| |
PU BK | RD | DFT | CONDUCTORS ONLY |
RD |
|
| |
|
|
| |
MAIN |
|
|
|
FIELD WIRING
HIGH VOLTAGE LOW VOLTAGE
COMPONENT CODE
|
|
|
C | CONTACTOR | |
CH | CRANKCASE HEATER | |
CM | OUTDOOR FAN MOTOR | |
COMP | COMPRESSOR | |
DC | DEFROST CONTROL | |
DFT | DEFROST THERMOSTAT | |
FC | FAN CAPACITOR | |
HVDR | HIGH VOLTAGE DEFROST RELAY | |
IO | INTERNAL OVERLOAD | |
LPS | LOW PRESSURE SWITCH | |
LVDR | LOW VOLTAGE DEFROST RELAY | |
LVJB | LOW VOLTAGE JUNCTION BOX | |
RVC | REVERSING VALVE COIL |
R | DFT |
|
|
|
|
| DC |
| |
|
| DFT | C | |
|
| Y | ||
|
|
|
| |
R | LVDR | W2 |
|
|
|
|
| ||
|
| O |
| RVC |
|
|
|
| |
|
| O | LPS | C |
|
|
| ||
R |
|
|
| C |
| O | W2 | Y |
|
INDOOR POWER
SUPPLY
NOTES:
1.TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT.
USE N.E.C. CLASS 2 WIRE
BEFORE SERVICING OR INSTALLING THIS SOURCES MAY BE PRESENT. FAILURE TO PROPERTY DAMAGE, PERSONAL INJURY OR |
date wiring.
25
AUX | T2 |
|
|
IO | YL | LPS | YL |
|
| ||
BK | BK |
|
|
| CH |
|
|
CM | (IF USED) |
|
|
|
|
|
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
DEATH. |
GSH130363AF