Goodmans RT6212008x5 Wiring, Diagrams, GSH130363AF GSH13048-604AC, wiring, Power Power Property

Models: GSH 13 SEER - 3 Phase Split System Heat Pump RT6212008x5

1 26
Download 26 pages 25.74 Kb
Page 26
Image 26
CONTROL BOX

26

Wiring is subject

CONTROL BOX

DC

 

 

 

 

LVJB

 

 

 

 

 

 

 

 

 

 

 

RD

 

R

 

 

 

 

 

 

 

WH

 

W2

 

NOTE 1

 

 

OR

 

O

 

 

 

 

 

 

 

 

 

YL

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR POWER SUPPLY

SEE RATING PLATE

WIRING

to change. Always refer to the

DF2

HLVJBCOLOR CODEBK V WIRING CODEPOWER POWER PROPERTY

LVDR

D

BK

 

R

 

DF1

 

 

C Y O O W2 R R DFT

BL OR WH RD

YL BK RD RD

COLOR CODE

BK ---------------

BLACK

BL ---------------

BLUE

BL/PK ----------

BLUE/PINK STRIP

BR ---------------

BROWN

OR ---------------

ORANGE

PU ---------------

PURPLE

RD ---------------

RED

WH --------------

WHITE

YL ---------------

YELLOW

YL/PK -----------

YELLOW/PINK STRIP

WIRING CODE

FACTORY WIRING

L1 COMPONENT CODE

T1

T2 DEATH

C

T2

T1

THIS TOGSH130363AF GSH130[48-60]4ACManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background COMP

 

 

 

 

T3

DF1

 

 

 

 

HVDR

 

 

 

 

DF2

 

 

 

 

IO

A

U

X

 

 

 

 

 

M

 

 

CM

A

 

 

I

 

 

N

T3

L2

C

FC

C L3

HIGH VOLTAGE! DISCONNECT ALL UNIT. MULTIPLE DO SO MAYCAUSE

DIAGRAMS

wiring

BK

BK YL

 

 

BL

 

BK

RD

 

BL

T1

T2

T3

RD

 

 

 

 

HIGH VOLTAGE Manual background LOW VOLTAGE

OPTIONAL HIGH VOLTAGE Manual backgroundManual background

CH

(IF USED)

POWER POWER PROPERTY

diagram on the unit for the most up-

YL

L1

L2

L3

YL

BK

BK

C

 

 

 

RD

Manual background PUManual background

FC

YL BK

RD

BK RVC BK

 

COMP

 

 

 

 

 

 

 

 

 

 

 

 

T1

T3

EQUIPMENT GROUND

NOTE 2

BR

RD

PU BK

DFT

RD

 

 

 

MAIN

 

 

BR

FIELD WIRING

HIGH VOLTAGE Manual backgroundManual backgroundManual backgroundManual backgroundManual background LOW VOLTAGE

COMPONENT CODE

C ---------------

CONTACTOR

CH -------------

CRANKCASE HEATER

CM ------------

OUTDOOR FAN MOTOR

COMP --------

COMPRESSOR

DC -------------

DEFROST CONTROL

DFT -----------

DEFROST THERMOSTAT

FC -------------

FAN CAPACITOR

HVDR --------

HIGH VOLTAGE DEFROST RELAY

IO --------------

INTERNAL OVERLOAD

LPS ------------

LOW PRESSURE SWITCH

LVDR ---------

LOW VOLTAGE DEFROST RELAY

LVJB ----------

LOW VOLTAGE JUNCTION BOX

RVC -----------

REVERSING VALVE COIL

R

DFT

 

 

 

 

 

DC

 

 

 

DFT

C

 

 

Y

 

 

 

 

R

LVDR

W2

 

 

 

 

 

 

 

O

 

RVC

 

 

 

 

 

 

O

LPS

C

 

 

 

R

 

 

 

C

 

O

W2

Y

 

INDOOR POWER

SUPPLY

NOTES:

1.TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK AND INDOOR THERMOSTAT.

2.USE COPPER CONDUCTORS ONLY.

BEFORE SERVICING OR INSTALLING SOURCES MAY BE PRESENT. FAILURE DAMAGE, PERSONAL INJURY OR

GSH130[36-48]3AE; GSH130603AC;

to-date wiring.

AUX

T2

 

 

IO

YL

LPS

YL

 

 

BK

BK

 

 

 

CH

 

 

CM

(IF USED)

 

 

 

 

 

CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.

USE N.E.C. CLASS 2 WIRE

0140R00022P-B

DEATH

THIS TO

.

 

GSH130363AF GSH130[48-60]4AC

Page 26
Image 26
Goodmans RT6212008x5 Wiring, Diagrams, GSH130363AF GSH13048-604AC, wiring, Power Power Property, This To, Death, Lvjb