Installation

Connect the Fluid Lines

1.Use grounded fluid hoses.

a.The pump fluid outlet (J) on the 400 and 1200 Series Pumps is 1 npt(f) .

b.The pump fluid outlet (J) on the 2500 Series Pump is 3/4 npt(f).

2.Install a fluid filter (F) and drain valve (E) near the fluid outlet. See Fig. 3.

WARNING

A fluid drain valve (E) is required in your system to relieve pressure in the fluid outlet hose (H) if the hose becomes plugged. See Fig. 3. Install a drain valve close to the pump’s fluid outlet. The drain valve reduces the risk of property damage or serious bodily injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids.

WARNING

SUCTION HAZARD

Never place your hands on or near the pump fluid inlet. Powerful suction could cause serious bodily injury.

3.Install a control device, such as a gun, dispensing valve, or shutoff valve, on the grounded fluid hose (H).

Connect the Fluid Suction Line

CAUTION

The pump must be suction fed in order to operate properly. Pressure feeding or exceeding 15 psi (104 kPa, 1.04 bar) maximum fluid inlet pressure may cause premature bellows seal failure.

Connect the fluid suction hose (S) to the pump fluid inlet (M). See Fig. 4.

DThe pump fluid inlet (M) is 1.25 npt(f).

DThe maximum suction lift is 15 ft (4.57m) for the 400 Series and 1200 Series Pumps, and 6 ft (1.83 m) for the 2500 Series Pump.

J

H

F

M

E

02325

Fig. 3

8 307843

Page 8
Image 8