Installation
Mounting the Pump
D400 and 1200 Series Pumps: Mount the pump with the accumulators in the top position as shown in Fig. 1. The accumulators must be in the position shown or the pump will not prime.
DBe sure the pump is securely bolted to its mounting and that the mounting can support the weight of the pump, hoses, and stress caused during operation.
DThe outlet manifold can be removed and turned 180 degrees to change the direction of the outlet and ease installation, as shown in Fig. 3.
General Information
DThe installation shown in Fig. 4 is only a guide for selecting and installing system components. Con- tact your Graco distributor for assistance in plan- ning a system to suit your needs.
DSee pages 38 through 43 for accessories and kits available from Graco. Always use Genuine Graco Parts and Accessories.
DUse a thread sealant compatible with the fluid being pumped on all male pipe threads. Tighten all con- nections firmly to avoid air or fluid leaks.
DReference numbers and letters in parentheses in the text refer to the figure illustrations.
accumulators
02321
Fig. 1
6 307843