Graco 117256 Series C, 249020 Series B Operation, Transceiver Diagnostics, Function Description

Models: 249021 Series B 120108 Series C 249020 Series B 249885 Series B 117256 Series C 249884 Series B

1 18
Download 18 pages 30.32 Kb
Page 13
Image 13

Operation

Operation

Once the Matrix system is installed, you can verify that the Transceiver is functioning correctly by observing each component’s indicator lights. Once verified, no additional service or maintenance is necessary.

M

L

 

 

K

 

 

J

 

 

H

 

 

FIG. 13

Transceiver See FIG. 13

 

 

 

 

 

 

Function

Description

 

 

Power - Green light (H)

When lit, indicates the unit is receiving AC power.

 

 

PC IN - Red light (J)

Flashing light indicates transmission from the PC to the Transceiver.

 

 

PC OUT - Red light (K)

Flashing light indicates transmission from the Transceiver to the PC.

 

 

RF IN - Red light (L)

Flashing light indicates RF signal received from Matrix or other RF source.

 

 

RF OUT - Red light (M)

Flashing light indicates valid Matrix RF signal data transmitted.

 

 

PC IN & RF OUT flashing (J & M)

Data from PC is being sent out via RF.

 

 

PC OUT & RF IN flashing (K & L)

Valid data received by Transceiver and sent to the PC.

 

 

 

Transceiver Diagnostics

Indicator

Diagnostic Definition

 

 

No green power

Indicates that AC power is not being received. Verify that the power cord is securely plugged into

light (H)

the component and the AC power outlet.

 

 

 

Verify that the AC power outlet is “live”.

 

 

No light on PC

Indicates that the PC is not communicating. Verify that the computer cable is securely plugged into

IN (J)

the back of the Transceiver and the communications port of the PC. Complete the Signal Strength

 

Test on the Matrix Application screen to verify signal from the PC to the Transceiver.

 

 

No light on PC

Indicates that the Transceiver is not communicating to the PC when receiving information from

OUT (K)

other Matrix components. Verify that the RF IN indicator is lit. If lit, verify computer cable is securely

 

connected. If so, replace Transceiver.

 

 

No light on RF

Indicates no transmission is being received by the Transceiver. Components may be too far out of

IN (L)

range for proper RF communications. Verify Matrix components are programmed, have power, are

 

functioning correctly, and are within RF communication range. Replace Transceiver if all other com-

 

ponents are working properly and are within appropriate distance.

 

 

Constant RF

System is in a RF communication “lock up”. Applies to all.

OUT (M) light

 

on

 

 

 

No light on RF

No RF communication transmitted from Transceiver to the Matrix system. Verify that the computer

OUT (M)

cable is securely plugged into the back of the Transceiver and the communications port of the PC.

 

Complete the Signal Strength Test on the Matrix Application screen to verify signal from PC to the

 

Transceiver and RF OUT from Transceiver.

 

 

309498H

13

Page 13
Image 13
Graco 117256 Series C Operation, Transceiver Diagnostics, Function Description, Indicator Diagnostic Definition