Installation Instructions
NOTE: For 262326 (4043 BD) units, skip to step 6.
1.Remove hex plug from the pump manifold using the wrench size listed in table 1.
4. Remove elbow fitting from the pump.
ti17842a
2.Install tapped hex plug (4) supplied with kit and torque to the specification in Table 2.
ti17843a
3. Remove pressure gauge from elbow fitting.
ti17844a
ti17845a
5. Install pressure gauge in the tapped valve cover.
ti17846a
6.Install the bleeder valve (1) into the pump in the previ- ous pressure gauge location. For 4043 BD units the plug must be removed prior to installing the bleeder valve.
ti17847a