Setup
Setup
1.Apply thread sealant to the male threads of the air needle valve (54) and the quick dis- connect fitting (55). Install into inlet port (AK).
1Apply thread sealant
3.Use labels (25) provided to identify the appropriate pump for your material.
25
1
55
AK
54
TI17171a
FIG. 4
2. Apply thread sealant to the male outlet fit- ting (BC) (not supplied) and insert into the outlet port (AL).
1 Apply thread sealant
AL
1
BC
TI17172a
FIG. 5
ti11649a
FIG. 6
4.Lubricate the bung adapter (16) inside diameter and mounting threads. Ensure the gasket is in place and screw the bung adapter (16) securely into the bunghole of the drum. Insert the pump through the adapter (16) and lock it in place.
16
TI17173a
FIG. 7
312766N | 11 |