Graco 308738C Service, Disconnecting the Displacement Pump, Reconnecting the Displacement Pump

Models: 308738C

1 16
Download 16 pages 59.75 Kb
Page 11
Image 11
Service

Service

Disconnecting the Displacement Pump

Disconnecting the Displacement Pump WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.

Flush the pump if possible. Stop the pump at the

 

bottom of its stroke. Relieve the pressure.

2.

Disconnect the air and fluid hoses. Unscrew the

 

bung adapter (4) from the bung hole in the drum

 

cover and pull the pump out of the drum. Note the

 

relative position of the fluid outlet (N) to the air inlet

 

(P). See Fig. 3.

3.

Unscrew the tie rod locknuts (7) from the tie rods

 

(6). Remove the cotter pin (8). Carefully pull the

 

displacement pump (2) off the air motor (1).

1Lubricate.

2Torque to 27 to 41 NSm (20 to 30 ft-lb).

1

 

 

 

 

P

6

9

1

 

R

 

Unscrew the displacement rod (R) from the air

motor (1). Inspect the o-ring (9).

4. Refer to manual 307044 for displacement pump

service. To service the air motor, refer to manual

306982.

S

27

5

4

8

Reconnecting the Displacement Pump N

Reconnecting the Displacement Pump

1.Lubricate the o-ring (9) and check that it is in place on the displacement rod (R).

2.Orient the fluid outlet (N) to the air inlet (P) as noted in step 2 under Disconnecting the Displacement Pump. Position the displacement pump (2) on the tie rods (6). See Fig. 3.

3.Screw the displacement rod (R) into the shaft of the air motor (1) until the pin holes are aligned. Install the cotter pin (8). Screw the locknuts (7) onto the tie rods (6) loosely.

4.Mount the pump and reconnect all hoses. Reconnect the ground wire if it was disconnected during repair. Tighten the packing nut (S). Fill the wet-cup with Graco Throat Seal Liquid or compatible solvent.

5.Tighten the tie rod locknuts (7) evenly, and torque to 27 to 41 NSm (20 to 30 ft-lb). Start the pump and run it at about 2.8 bar (0.28 MPa, 40 psi) air pressure, to check that it is operating properly.

Manual background 2

07200

Fig. 3

308738 11

Page 11
Image 11
Graco 308738C manual Service, Disconnecting the Displacement Pump, Reconnecting the Displacement Pump