Optional Gun Air Regulator 235119

Operation

Optional Gun Air Regulator 235119

NOTE:

DInstalling the gun air inlet regulator adds a pressure drop that could limit the air cap pressure.

DSee Accessories on page 11 for air regulator replacement parts.

1.Pull up the gun regulator adjustment knob lock-ring (L); this allows the knob to turn. See Fig. 5.

2.Set the gun air pressure at zero by turning the regulator adjustment knob (K) fully counterclock- wise.

3.Turn on the air supply to the gun.

4.Turn the regulator adjustment knob (K) clockwise to increase the air pressure to the gun.

Manual background WARNING

Never exceed 100 psi (7 bar) Maximum Working

 

 

Air Pressure to the gun. Exceeding the maxi-

 

 

 

Fig. 5

mum working pressure of the gun or any other

 

 

system component could cause component

 

 

rupture, which could result in serious injury and

 

 

property damage.

 

 

 

 

 

5. Push the adjustment knob lock-ring (L) down to

 

 

hold the pressure setting.

 

 

L

K

7614A

308791 5

Page 5
Image 5
Graco 308791E important safety instructions Optional Gun Air Regulator, Operation