Optional Hose Position
Fluid inlet swivels and air quick disconnect fitting point to rear. If desired, these positions can be changed so hoses travel downward.
CAUTION
To prevent
1. Follow Pressure Relief Procedure, page 15. Also
relieve system pressure, see proportioner manual.
2. Disconnect air (D) and remove fluid manifold (M).
M
D
TI2554A
3. Disconnect fluid hoses from inlet swivels (A, B).
Remove swivels. Remove plugs from optional inlets (P).
B
A
P
TI2417A
Optional Configurations
4. Apply thread sealant to plugs (12c), elbows (50*),
and male threads of swivels (A, B). Install elbows (50*) in optional inlets (P), facing down. Install swivels (A, B) in elbows. Be sure to install A swivel (smaller) in A side. Install plugs where swivels had been. Torque all parts to
Elbows (50*) are not included with spatter spray gun.
|
| 12c |
B |
| 50* |
|
| |
| P | A |
| TI2646A | |
|
|
5. Connect A and B hoses to A and B swivels.
6. Remove fitting (D) and plug (J). Reverse positions.
Apply thread sealant and torque to
D
TI2540A
J
7. Attach fluid manifold. Connect air. Return gun to
service.