Troubleshooting

PROBLEM

CAUSE

SOLUTION

 

 

 

 

 

 

A and/or B fluid in gun air section.

Damaged side seals (18c).

Replace, page 29.

 

 

 

 

Damaged mix chamber (19).

Replace, page 29.

 

 

 

 

Damaged side seal o-rings (18d,

Replace, page 29.

 

18e).

 

 

 

 

 

Tightened air cap with fluid valves

Close valves first.

 

(12b) open.

 

 

 

 

Fluid mist from mix chamber or air

Damaged side seals (18c).

Replace, page 29.

cap.

 

 

 

 

 

 

Damaged side seal o-rings (18d,

Replace, page 29.

 

18e).

 

 

 

 

 

Damaged mix chamber (19).

Replace, page 29.

 

 

 

Excessive overspray.

Too much cleanoff air.

Reduce, page 13.

 

 

 

Rapid buildup of material on air cap.

Plugged air cap holes.

Clean, page 20.

 

 

 

 

Too little cleanoff air.

Increase, page 13.

 

 

 

 

Damaged/missing fluid housing

Replace, page 29.

 

o-ring (23).

 

 

 

 

 

Damaged front o-ring (3).

Replace, page 29.

 

 

 

Reduced cleanoff air.

Damaged front o-ring (3).

Replace, page 29.

 

 

 

Excessive cleanoff air when fluid

Damaged/missing fluid housing

Replace, page 29.

valves are closed and gun is trig-

o-ring (23).

 

gered.

 

 

 

 

 

Fluid does not shut off when fluid

Damaged fluid valves (12b).

Replace.

valves are closed.

 

 

 

 

 

Burst of air from muffler when gun is

Normal.

No action required.

triggered.

 

 

 

 

 

Steady air leakage from muffler.

Damaged air valve o-rings (24).

Replace, page 33.

 

 

 

 

Damaged piston o-rings (16, 17).

Replace, page 32.

 

 

 

Air leakage from front air valve.

Damaged air valve o-rings (24).

Replace, page 33.

 

 

 

Air leak around lock ring.

Damaged o-ring (21).

Replace, page 29.

 

 

 

Cannot tighten retaining ring (9) until

Air cap (10) assembled before retain-

Install retaining ring (9) first, then air

it bottoms out.

ing ring (9).

cap (10), page 30.

 

 

 