High Pressure Setting
Performance Charts
200 (1.38, 13.8)
160 (1.10, 11.0)
Fluid Pressure
Approximate Cycles per Minute
50 | 100 | 150 | 200 | 250 |
Operating Air Pressure
A
100 psi (0.7 MPa, 7.0 bar)
B
70 psi (0.48 MPa, 4.8 bar)
C
40 psi (0.28 MPa, 2.8 bar)
D
20 psi (0.14 MPa, 1.4 bar)
PSI (MPa, bar)
120 (0.83, 8.3)
80 (0.55, 5.5)
40 (0.28, 2.8)
0
A
B
C
D
0 | 10 | 20 | 30 | 40 | 50 |
| (38) | (76) | (114) | (151) | (189) |
Fluid Flow — gpm (lpm)
How to Read the Charts
1.Locate fluid flow rate along bottom of chart.
2.Follow vertical line up to intersection with selected operating air pressure curve.
3.Follow left to scale to read fluid outlet pressure (top chart) or air consumption (bottom chart)
120
(3.4)
96
(2.7)
72
(2.0)
scfm (Nm3/min.)
48
(1.4)
24
(0.7)
0
Air Consumption
Approximate Cycles per Minute
50 | 100 | 150 | 200 | 250 |
A
B
C
D
0 | 10 | 20 | 30 | 40 | 50 |
| (38) | (76) | (114) | (151) | (189) |
Fluid Flow — gpm (lpm)
334014A | 19 |