Graco 334014A important safety instructions High Pressure Setting

Models: 334014A

1 22
Download 22 pages 28.45 Kb
Page 19
Image 19

High Pressure Setting

Performance Charts

200 (1.38, 13.8)

160 (1.10, 11.0)

Fluid Pressure

Approximate Cycles per Minute

50

100

150

200

250

Operating Air Pressure

A

100 psi (0.7 MPa, 7.0 bar)

B

70 psi (0.48 MPa, 4.8 bar)

C

40 psi (0.28 MPa, 2.8 bar)

D

20 psi (0.14 MPa, 1.4 bar)

PSI (MPa, bar)

120 (0.83, 8.3)

80 (0.55, 5.5)

40 (0.28, 2.8)

0

A

B

C

D

0

10

20

30

40

50

 

(38)

(76)

(114)

(151)

(189)

Fluid Flow — gpm (lpm)

How to Read the Charts

1.Locate fluid flow rate along bottom of chart.

2.Follow vertical line up to intersection with selected operating air pressure curve.

3.Follow left to scale to read fluid outlet pressure (top chart) or air consumption (bottom chart)

120

(3.4)

96

(2.7)

72

(2.0)

scfm (Nm3/min.)

48

(1.4)

24

(0.7)

0

Air Consumption

Approximate Cycles per Minute

50

100

150

200

250

A

B

C

D

0

10

20

30

40

50

 

(38)

(76)

(114)

(151)

(189)

Fluid Flow — gpm (lpm)

334014A

19

Page 19
Image 19
Graco 334014A important safety instructions High Pressure Setting