Graco 334014A Fluid Temperature Range, Wetted parts, Non-wetted external parts

Models: 334014A

1 22
Download 22 pages 28.45 Kb
Page 21
Image 21

Technical Data

Sound Power (measured per ISO-9614–2)

 

 

At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm

 

 

Low Pressure Setting

 

78

dBa

High Pressure Setting

 

91

dBa

At 100 psi (0.7 MPa, 7.0 bar) and full

flow

 

 

Low Pressure Setting

 

90

dBa

High Pressure Setting

 

102 dBa

Sound Pressure (tested 3.28 ft [1 m] from

equipment)

 

At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm

 

 

Low Pressure Setting

 

84

dBa

High Pressure Setting

 

96

dBa

At 100 psi (0.7 MPa, 7.0 bar) and full

flow

 

 

Low Pressure Setting

 

84

dBa

High Pressure Setting

 

96

dBa

Wetted parts

 

aluminum plus the material(s) chosen for seat, ball,

 

 

and diaphragm options.

Non-wetted external parts

 

aluminum, coated carbon steel

Fluid Temperature Range

NOTICE

Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid operating temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.

 

Fluid Temperature Range

Diaphragm/Ball Material

Fahrenheit

Celsius

 

 

 

Santoprene® (SP)

-40° to 180°F

-40° to 82°C

 

 

 

334014A

21

Page 21
Image 21
Graco 334014A Fluid Temperature Range, Wetted parts, Non-wetted external parts, Diaphragm/Ball Material