WatchDogProtection System (Not Available on All Units)

WatchDogProtection

System (Not Available on All Units)

Pump stops automatically when material pail is empty.

To Activate:

1. Perform Startup.

ti7398a

2.Premium units with digital display:

Turn WatchDog switch ON and WD ON displays. EMPTY displays/flashes and pump stops when Watchdog protection system detects an empty material pail.

ti6224a

3.Turn WatchDog switch OFF. Add material or reprime sprayer. Turn pump switch OFF and ON to reset WatchDog protection system. Turn WatchDog switch back ON to continue to monitor material level.

ti7399a

TIA

Fast Flush

To flush the hose and gun at an accelerated speed, per- form the following steps:

1.Perform steps 1 - 3 of Cleanup, page 16.

2.Hold gun trigger in and turn prime valve down to DRAIN position and then over to FAST FLUSH.

ti14849a

3. Continue flushing system until fluid appears clear.