Graco 3A0156B important safety instructions Setup

Models: 3A0156B

1 20
Download 20 pages 51.8 Kb
Page 9
Image 9

Setup

1.Standard Units Only: Connect Graco airless hose to sprayer. Tighten securely.

ti14843a

2.Standard Units Only: Connect other end of hose to gun and tighten securely.

Setup

6.Fill throat packing nut with Graco TSL to prevent premature packing wear. Do this each time you spray.

ti13453a

7. Turn power OFF.

ti4265a

ti4265a

ti13031a

3. Engage gun trigger safety.

ti10166a

4. Remove tip guard.

ti2769a

5. Check inlet strainer for clogs and debris.

8.Plug power supply cord into a properly grounded electrical outlet.

ti2810a

9. Turn prime valve down to DRAIN position.

ti14842a

10.Place pump in grounded metal pail partially filled with flushing fluid. Attach ground wire to pail and to true earth ground. Perform steps 1 - 5 of Startup to flush out storage oil shipped in sprayer. Use water to flush water-base paint and mineral spirits to flush oil-base paint and storage oil.

ti14844a

3A0156B

9

Page 9
Image 9
Graco 3A0156B important safety instructions Setup