Cleanup

Cleanup

1.Perform Pressure Relief Procedure (page 8), steps 1 - 4. Remove siphon tube set from paint and place in flushing fluid. Remove tip guard from gun.

ti2756a

NOTE: Use water for water-base paint, mineral spirits for oil-base paint, or other solvents recommended by manufacturer.

2.Turn power ON. Turn prime valve forward to SPRAY position.

ti4266a

ti14845a

3.Increase pressure to 1/2. Hold gun against paint pail. Take trigger safety OFF. Trigger gun until flush- ing fluid appears.

1/2

ti14846a

ti4271a

4.Move gun to waste pail, hold gun against pail, trig- ger gun to thoroughly flush system. Release trigger and put trigger safety ON.

ti14847a

5.Turn prime valve down to DRAIN position and allow flushing fluid to circulate until flushing fluid appears clear.

ti14842a

6.Turn prime valve forward to SPRAY position. Trigger gun into flushing pail to purge fluid from hose.

ti14845a

ti14847a

7.Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. Turn power OFF

PAINT

ti2820a

FLUSH

8.Turn prime valve down DRAIN position. Unplug sprayer.

ti2718a

ti14842a