Graco 3A0156B important safety instructions Grounding, Pails

Models: 3A0156B

1 20
Download 20 pages 51.8 Kb
Page 7
Image 7

Grounding

The sprayer must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.

The sprayer cord includes a grounding wire with an appropriate grounding contact.

The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Grounding

Pails

Solvent and oil/based fluids: follow local code. Use only conductive metal pails, placed on a grounded sur- face such as concrete.

Do not place pail on a nonconductive surface such as paper or cardboard which interrupts grounding continu- ity.

ti2810a

ti4297a

Do not modify plug! Tampering with the plug will result in a voided warranty. If plug will not fit in outlet, have grounded outlet installed by a qualified electrician. Do not use an adapter.

Power Requirements

100-120V units require 100-120 VAC, 50/60 Hz, 15A, 1 phase.

230V units require 230 VAC, 50/60 HZ, 10A, 1 phase.

Extension Cord

Use an extension cord with an undamaged ground con- tact. If an extension cord is necessary, use a 3-wire, 12

AWG (2.5 mm2) minimum.

Ground

120 volt plug

ti5850a

Grounding a metal pail: connect a ground wire to the pail by clamping one end to pail and other end to a true earth ground.

ti14840a

To maintain grounding continuity when flushing or relieving pressure: hold metal part of spray gun firmly to side of a grounded metal pail. Then trigger gun.

ti13243a

3A0156B

7

Page 7
Image 7
Graco 3A0156B important safety instructions Grounding, Pails