Compressor Replacement

Compressor Replacement

Removal

1.Perform Pressure Relief Procedures, page 7.

2.Remove are line (145) from compressor.

145

ti17366a

3.Remove four screws (1) and two nuts (15) securing top belt guard (108).

15

1

108

ti16822a

4.Loosen four mounting bolts on compressor to reduce compressor belt tension.

5. Remove top belt guard (108).

108

ti16821a

6.Remove belt from compressor pulley. If belts needs to be replaced, see Compressor Belt and Hydrau- lic Pump Belt Replacement, page 9.

7.Unscrew relief valve assembly from the old com- pressor.

ti17369a

ti17364a

14