Troubleshooting
Programmable Skipline Controller
PROBLEM | CAUSE |
| SOLUTION |
|
|
|
|
Controller not turning on | Fuse, battery, or wiring | 1. | Check fuse located next to 12V |
|
|
| RoadLazer battery. |
|
| 2. | Check battery voltage. Replace if |
|
|
| necessary. |
|
| 3. | Inspect wiring at battery for corro- |
|
|
| sion. Inspect control cable for dam- |
|
|
| age. |
|
|
|
|
Controller shutting down or cutting out | Battery or wiring | 1. | Check battery voltage. A weak bat- |
during striping |
|
| tery can drop voltage low enough to |
|
|
| cause intermittent shut down. |
|
| 2. | Check wiring. |
|
| 3. | Ground control box to vehicle chas- |
|
|
| sis. |
|
|
|
|
System Delay not turning on | System not configured for striping or is | 1. | Remove gun arm from stowed posi- |
| shut off |
| tion, and start up engine. System |
|
|
| delay will not turn on unless you are |
|
|
| ready to stripe. |
|
| 2. | System Delay must be turned back |
|
|
| on after engine is turned off. |
|
|
|
|
Controller not displaying MPH (KM/H), | Gun arm sensor or sensor wiring | 1. | Check sensor (524) located on gun |
or readout is erratic |
|
| arm wheel assembly. Set sensor |
|
|
| approximately 1/8 in. (3 mm) from |
|
|
| target plate. |
|
| 2. | Check sensor head for damage. |
|
|
| Replace if damaged. |
|
| 3. | Check sensor wiring by removing |
|
|
| solenoid valve cover (519). |
|
|
|
|
System Delay actual distance not pre- | Programmed distance needs fine tuning | 1. | This is usually true. Get it as close as |
cisely matching programmed distance |
|
| possible, then spray one additional |
|
|
| test line and try to hit the start point. |
|
| 2. | Measure difference between start |
|
|
| point and where paint guns turn on. If |
|
|
| paint guns turn on before start point, |
|
|
| add measured difference to current |
|
|
| system delay distance. If paint guns |
|
|
| turn on after start point, subtract |
|
|
| measured difference. |
|
|
|
|
22 | 3A1696C |