Pressure Relief Procedure
WARNING
PRESSURIZED EQUIPMENT HAZARD
The equipment stays pressurized until pressure is manually relieved. To reduce the risk of a serious injury from pressurized fluid, accidental spray from the gun, or splashing fluid, follow the Pressure Relief Procedure whenever you
DAre instructed to relieve the pressure
DStop spraying
DCheck or service any of the system equipment
DInstall or clean the fluid nozzles
113
206c | 21/ | 2 | gallon | 2 quart |
| ||||
|
|
| ||
|
|
| 8069A | 02882A |
1.Turn off air supply to gun, and turn off turbine sprayer.
WARNING
The turbine hose outlet may be hot. Carefully check the hose end before you remove the hose.
2.If using remote pressure pot, relieve pressure by following these steps (see Fig. 1):
a.Turn off air supply to pressure pot.
b.
Pull pressure relief valve ring (206c) until pressure is completely relieved.
Turn out pressure relief knob (113) about one turn. Wait until pressure is completely relieved before you remove cover. Close knob.
Fig. 1
3.Elevate spray gun and pull trigger to allow fluid in fluid hose to drain back into remote pressure pot.
4.If using a spray gun cup:
Unlatch cup cover, and loosen or remove cup from cover to relieve cup pressure.
5.Clean spray gun and cup as instructed in turbine gun manual 308336 or 308810.
Turbine Kit Installation
WARNING
Turn off the turbine and unplug the power cord for these procedures.
Use these procedures to install the
3.Carefully lift and remove turbine base plate (2) from cover (1). Place turbine upright on work surface.
27
7
2
Replace existing parts with kit parts
Turbine Disassembly
1.If necessary, clean and replace filter according to maintenance procedure in manual 308808.
2.Place turbine upside down on work surface. Remove four cap screws (27) and bumpers (7) as shown in Fig. 2.
2308924
Fig. 2
1
7949A