Troubleshooting
Electrical
Symptom: Sprayer does not run or stops running.
Perform Pressure Relief Procedure; page 8.
•Plug sprayer into correct voltage, grounded outlet
•Set power switch OFF for 30 seconds and then ON again (this ensures sprayer is in normal run mode).
•Turn pressure control knob clockwise 1/2 turn
•View digital display
To avoid electrical shock or moving parts hazards when covers are removed for troubleshooting, wait 30 sec- onds after unplugging power cord for stored electricity to dissipate. Keep clear of electrical and moving parts during troubleshooting procedures.
If no digital display is available, use control board status light to troubleshoot prob- lems: Turn ON/OFF switch OFF, remove control cover and then turn power back ON. Observe status light. Blinking LED to- tal count equals digital error code i.e., two blinks equals E=02.
TYPE OF PROBLEM | WHAT TO CHECK |
| HOW TO CHECK |
|
|
|
|
Sprayer does not run at all | See flow chart, page 19. |
|
|
|
|
|
|
Digital display is blank |
|
|
|
|
|
|
|
Control board status light never |
|
|
|
lights |
|
|
|
|
|
|
|
Sprayer does not run at all | Check transducer or transducer | 1. | Make sure there is no pressure in the system (see |
| connections |
| Pressure Relief Procedure, page 8). Check fluid |
Digital display shows E=02 |
| ||
|
| path for clogs, such as clogged filter. | |
|
|
| |
|
| 2. | Use airless paint spray hose with no metal braid |
|
|
| 1/4 in. x 50 ft minimum. Smaller hose or metal braid |
|
|
| hose may result in |
|
| 3. | Set sprayer to OFF and disconnect power to |
Control board status light blinks |
| ||
|
| sprayer. | |
2 times repeatedly |
|
| |
| 4. | Check transducer and connections to control board. | |
|
| ||
|
| 5. | Disconnect transducer from control board socket. |
|
|
| Check that transducer and control board contacts |
|
|
| are clean and secure. |
|
| 6. | Reconnect transducer to control board socket. |
|
|
| Connect power, set sprayer ON and control knob |
|
|
| 1/2 turn clockwise. If sprayer does not run properly, |
|
|
| set sprayer to OFF and go to next step. |
|
| 7. | Install new transducer. Connect power, set sprayer |
|
|
| ON and control knob 1/2 turn clockwise. Replace |
|
|
| control board if sprayer does not run properly. |
|
|
|
|
3A0157B | 13 |