Setup

Setup

1. Close fluid valves A and B.

TI2411A

2. Connect A (ISO) and B (RESIN) fluid hoses to fluid manifold.

B (RESIN)

TI2417A

A (ISO)

3. Engage piston safety lock, page 12.

TI3850a

4. Connect gun air whip hose (T) and air valve (U) to

main air hose. Attach fluid manifold (G) to gun.

T

G

U

TI3830a

To change position of fluid manifold or use optional fluid inlets, see pages 19 and 20.

5. Connect air line to quick coupler (D). Turn on air.

Open air valve (U). Air should flow from air cap around CeramTip (M). Open cleanoff air valve (K) about 1/4 to 1/2 turn, then adjust air flow as required.

K

M

D

U

TI3839a

 

To use optional air inlet, see page 20.

6. Adjust purge rod, page 15.

7. Turn on proportioner.

309856U

13