Installation
WARNING
SKIN INJECTION HAZARD
To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief
Procedure on page 4.
NOTE: Numbers and letters in parentheses in the text correspond to the reference numbers and letters in the text and drawings.
WARNING
SKIN INJECTION HAZARD
Be sure your system has a
accessories help reduce the risk of serious injury, including fluid injection, splashing in the eyes, or on the skin, or injury from moving parts, if you are adjusting or repairing the pump or gun.
1.The
2.The fluid drain valve assists in relieving fluid pressure in the displacement pump, hose, and gun; triggering the gun to relieve pressure may not be sufficient.
1.Connect a grounded fluid hose to the gun inlet.
2.With no tip installed, start the pump/sprayer. Flush it according to the instructions supplied with it. Prime the system with the fluid you are using.
3.Relieve the pressure.
B
A
9
8105
Fig. 1
4.WIth the gun safety latch engaged, unscrew the tip guard (9) and install the tip (A) and gasket (B) in the nut of the tip guard. Screw the assembly firmly onto the gun. TIghten with a wrench. See Fig. 1.
NOTE: Failure to install the tip gasket (B) will result in leaking.
5.Strain the fluid you are spraying if it contains particles which could clog the spray tip.
307010 5