Operation

DD

0365

45 43c

26

43g 31

1

20

0369A

Fig. 4

Selecting a Fluid Nozzle and Air Cap

WARNING

PRESSURIZED EQUIPMENT HAZARD

To reduce the risk of an injury, follow the Pressure Relief Procedure on page 11 before removing or installing a fluid nozzle and/or air cap.

The gun is supplied with a 0.059 in. (1.5 mm) fluid nozzle, P/N 185158, and air cap, P/N 193033. If your application requires a different nozzle and air cap combination, use instruction manual 307803 or consult your authorized Graco distributor to select the ap- propriate fluid nozzle and air cap. Install the air cap and fluid nozzle into the gun barrel as instructed in Air Cap/Nozzle/Resistor Stud Replacement, page 22.

Operating the Spray Gun

WARNING

PRESSURIZED EQUIPMENT HAZARD

To reduce the risk of an injury, follow the Pressure Relief Procedure on page 11 whenever you stop spraying and whenever you are instructed to relieve pressure.

WARNING

COMPONENT RUPTURE HAZARD

To reduce the risk of component rupture, which can cause serious injury, do not

exceed the maximum working pressure of the lowest rated system component. This equip- ment has a 100 psi (7 bar, 0.7 MPa) maximum working air and fluid pressure.

Follow the steps on page 13 to establish the correct fluid flow and air flow. Do not turn the ES ON-OFF lever to ON yet.

12 308131

Page 12
Image 12
Graco Inc 308131, 224400, 224200 Selecting a Fluid Nozzle and Air Cap, Operating the Spray Gun, Component Rupture Hazard