Setup

CAUTION

This equipment is compatible with most water-based materials. See the wetted parts in the Technical Data section and your fluid and solvent manufactur- er’s compatibility information.

I.Prepare the operator.

All persons who operate the system should be trained in the safe, efficient operation of all system compo- nents as well as the proper handling of the chemical coating. At a minimum, all operators should thoroughly read the safety, installation and operation sections of this manual and the component manuals.

II.Prepare the site.

1.Use a minimum 5 HP (3.7 kW) air compressor for efficient operation.

2.Clear obstacles and debris that could cause an unsafe operating environment.

3.Bring an air line from your compressed air supply to the pressure pot location. Be sure the air is dry and filtered. Install a bleed-type master air valve upstream from the pressure pot. When it is closed and the pressure pot air regulator (33) is opened, the bleed-type master air valve relieves all air pressure to the equipment components.

4.Ventilate the spray booth.

WARNING

TOXIC FLUID HAZARD

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth.

Never operate the spray gun unless ventilation fans are operating.

Check and follow all of the national, state and local codes regarding air exhaust velocity requirements.

4308455

Page 4
Image 4
Graco Inc 237413, 308455K, 237409 important safety instructions Setup, Prepare the operator, II. Prepare the site