See Fig. 1, on page 5.

Setup

III.Unpack the system.

1.In addition to the assembled unit, these compo- nents are packed loosely or separately: hose set, gun, instruction manuals. These are the manuals you should receive:

308369 Pressure pot

308167 Air regulator

312414 HVLP spray gun (Model 237413)

312414 Air spray gun (Model 237409)

IV. Connect the hose set and gun to the system.

1.Connect the air hose (43) between the gun air shutoff valve (17a) and the air inlet of the spray gun. These are 1/4–18 npsm swivel fittings.

2.Connect the fluid hose (40) between the fluid shutoff valve (18) and the fluid inlet of the spray gun. These are 3/8–18 npsm swivel fittings.

3.Verify that all fittings throughout the system are tightened securely.

V.Ground the system.

WARNING

FIRE AND EXPLOSION HAZARD To reduce the risk of static sparking, ground the pressure pot and all other equipment used or located in the spray area. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Also read FIRE AND EXPLOSION HAZARD on page 2.

Ground all of this equipment:

1.Pressure pot: One end of the ground wire (13) is already connected to the pressure pot. Connect the other end of the ground wire to a true earth ground.

2.Air compressor: Ground according to manufac- turer’s recommendations.

3.Object being sprayed: Ground according to local code.

4.Fluid supply container: Ground according to local code.

5.All solvent pails used when flushing: Ground according to local code. Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or card- board, which interrupts the grounding continuity.

6308455

Page 6
Image 6
Graco Inc 308455K, 237413, 237409 III. Unpack the system, IV. Connect the hose set and gun to the system, Ground the system